Analysis of the Aperture Function of the Scattering Volume of the Collimation System of the Scattering Computed Tomography of Steel Products with a Ring Detector.

Saved in:
Bibliographic Details
Title: Analysis of the Aperture Function of the Scattering Volume of the Collimation System of the Scattering Computed Tomography of Steel Products with a Ring Detector.
Authors: Zhuravskiy, E. E.1 (AUTHOR) zhuravskiy@tpu.ru, Belkin, D. S.1 (AUTHOR) Belkin@tpu.ru, Kapranov, B. I.1 (AUTHOR) introbob@mail.ru, Chakhlov, S. V.1 (AUTHOR) chakhlov@tpu.ru
Source: Russian Journal of Nondestructive Testing. Jun2020, Vol. 56 Issue 6, p506-515. 10p.
Subjects: Compton scattering, Emission tomography equipment, Detectors, Steel, Collimators, Positron emission
Abstract: This article discusses the features of the collimation system of a tomograph for monitoring steel products by Compton backscattering. The analysis of the aperture functions of the scattering volume for the ring-type detector with different sizes of the pinholes of the primary and secondary collimators is carried out. The efficiency of using a ring type detector is shown. Recommendations to select pinhole sizes of the primary and secondary collimators are given. An indirect estimation of the possible scanning depth of steel products is given. [ABSTRACT FROM AUTHOR]
Copyright of Russian Journal of Nondestructive Testing is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
Description
Abstract:This article discusses the features of the collimation system of a tomograph for monitoring steel products by Compton backscattering. The analysis of the aperture functions of the scattering volume for the ring-type detector with different sizes of the pinholes of the primary and secondary collimators is carried out. The efficiency of using a ring type detector is shown. Recommendations to select pinhole sizes of the primary and secondary collimators are given. An indirect estimation of the possible scanning depth of steel products is given. [ABSTRACT FROM AUTHOR]
ISSN:10618309
DOI:10.1134/S106183092006008X