Performance of a low gain avalanche detector in a medical linac and characterisation of the beam profile.

Saved in:
Bibliographic Details
Title: Performance of a low gain avalanche detector in a medical linac and characterisation of the beam profile.
Authors: Isidori, T (AUTHOR) ronan.mcnulty@ucd.ie, McCavana, P (AUTHOR), McClean, B (AUTHOR), McNulty, R (AUTHOR), Minafra, N (AUTHOR), Raab, N (AUTHOR), Rock, L (AUTHOR), Royon, C (AUTHOR)
Source: Physics in Medicine & Biology. 7/7/2021, Vol. 66 Issue 13, p1-10. 10p.
Subjects: Radiation dosimetry, Detectors, Radiation measurements, Linear accelerators, Picosecond pulses
Abstract: Low gain avalanche detectors can measure charged particle fluences with high speed and spatial precision, and are a promising technology for radiation monitoring and dosimetry. A detector has been tested in a medical linac where single particles were observed with a time resolution of 50 ps. The integrated response is similar to a standard ionising chamber but with a spatial precision twenty times finer, and a temporal precision over 100 million times better, with the capability to measure the charge deposited by a single linac pulse. The unprecedented resolving power allows the structure of the ∼3 μs linac pulses to be viewed and the 350 ps sub-pulses in the train to be observed. [ABSTRACT FROM AUTHOR]
© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 151509051
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Performance of a low gain avalanche detector in a medical linac and characterisation of the beam profile.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Isidori%2C+T%22">Isidori, T</searchLink> (AUTHOR)<i> ronan.mcnulty@ucd.ie</i><br /><searchLink fieldCode="AR" term="%22McCavana%2C+P%22">McCavana, P</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McClean%2C+B%22">McClean, B</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McNulty%2C+R%22">McNulty, R</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Minafra%2C+N%22">Minafra, N</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Raab%2C+N%22">Raab, N</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rock%2C+L%22">Rock, L</searchLink> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Royon%2C+C%22">Royon, C</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Physics+in+Medicine+%26+Biology%22">Physics in Medicine & Biology</searchLink>. 7/7/2021, Vol. 66 Issue 13, p1-10. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Radiation+dosimetry%22">Radiation dosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Detectors%22">Detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+measurements%22">Radiation measurements</searchLink><br /><searchLink fieldCode="DE" term="%22Linear+accelerators%22">Linear accelerators</searchLink><br /><searchLink fieldCode="DE" term="%22Picosecond+pulses%22">Picosecond pulses</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Low gain avalanche detectors can measure charged particle fluences with high speed and spatial precision, and are a promising technology for radiation monitoring and dosimetry. A detector has been tested in a medical linac where single particles were observed with a time resolution of 50 ps. The integrated response is similar to a standard ionising chamber but with a spatial precision twenty times finer, and a temporal precision over 100 million times better, with the capability to measure the charge deposited by a single linac pulse. The unprecedented resolving power allows the structure of the ∼3 μs linac pulses to be viewed and the 350 ps sub-pulses in the train to be observed. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=151509051
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1088/1361-6560/ac0587
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 1
    Subjects:
      – SubjectFull: Radiation dosimetry
        Type: general
      – SubjectFull: Detectors
        Type: general
      – SubjectFull: Radiation measurements
        Type: general
      – SubjectFull: Linear accelerators
        Type: general
      – SubjectFull: Picosecond pulses
        Type: general
    Titles:
      – TitleFull: Performance of a low gain avalanche detector in a medical linac and characterisation of the beam profile.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Isidori, T
      – PersonEntity:
          Name:
            NameFull: McCavana, P
      – PersonEntity:
          Name:
            NameFull: McClean, B
      – PersonEntity:
          Name:
            NameFull: McNulty, R
      – PersonEntity:
          Name:
            NameFull: Minafra, N
      – PersonEntity:
          Name:
            NameFull: Raab, N
      – PersonEntity:
          Name:
            NameFull: Rock, L
      – PersonEntity:
          Name:
            NameFull: Royon, C
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 07
              M: 07
              Text: 7/7/2021
              Type: published
              Y: 2021
          Identifiers:
            – Type: issn-print
              Value: 00319155
          Numbering:
            – Type: volume
              Value: 66
            – Type: issue
              Value: 13
          Titles:
            – TitleFull: Physics in Medicine & Biology
              Type: main
ResultId 1