Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure.

Saved in:
Bibliographic Details
Title: Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure.
Authors: Berry, D. B.1,2 (AUTHOR) dbberry@ucsd.edu, Galinsky, V. L.3 (AUTHOR), Hutchinson, E. B.4 (AUTHOR), Galons, J. P.5 (AUTHOR), Ward, S. R.1,6,7 (AUTHOR), Frank, L. R.3 (AUTHOR)
Source: Magnetic Resonance in Medicine. Oct2023, Vol. 90 Issue 4, p1582-1593. 12p.
Subjects: Diffusion magnetic resonance imaging, Diffusion tensor imaging, Diffusion gradients, Skeletal muscle, Diffusion measurements
Abstract: Purpose: Preliminary study to determine whether double pulsed field gradient (PFG) diffusion MRI is sensitive to key features of muscle microstructure related to function. Methods: The restricted diffusion profile of molecules in models of muscle microstructure derived from histology were systematically simulated using a numerical simulation approach. Diffusion tensor subspace imaging analysis of the diffusion signal was performed, and spherical anisotropy (SA) was calculated for each model. Linear regression was used to determine the predictive capacity of SA on the fiber area, fiber diameter, and surface area to volume ratio of the models. Additionally, a rat model of muscle hypertrophy was scanned using a single PFG and a double PFG pulse sequence, and the restricted diffusion measurements were compared with histological measurements of microstructure. Results: Excellent agreement between SA and muscle fiber area (r2 = 0.71; p < 0.0001), fiber diameter (r2 = 0.83; p < 0.0001), and surface area to volume ratio (r2 = 0.97; p < 0.0001) in simulated models was found. In a scanned rat leg, the distribution of these microstructural features measured from histology was broad and demonstrated that there is a wide variance in the microstructural features observed, similar to the SA distributions. However, the distribution of fractional anisotropy measurements in the same tissue was narrow. Conclusions: This study demonstrates that SA—a scalar value from diffusion tensor subspace imaging analysis—is highly sensitive to muscle microstructural features predictive of function. Furthermore, these techniques and analysis tools can be translated to real experiments in skeletal muscle. The increased dynamic range of SA compared with fractional anisotropy in the same tissue suggests increased sensitivity to detecting changes in tissue microstructure. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 168591188
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Berry%2C+D%2E+B%2E%22&quot;&gt;Berry, D. B.&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; dbberry@ucsd.edu&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Galinsky%2C+V%2E+L%2E%22&quot;&gt;Galinsky, V. L.&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Hutchinson%2C+E%2E+B%2E%22&quot;&gt;Hutchinson, E. B.&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Galons%2C+J%2E+P%2E%22&quot;&gt;Galons, J. P.&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Ward%2C+S%2E+R%2E%22&quot;&gt;Ward, S. R.&lt;/searchLink&gt;&lt;relatesTo&gt;1,6,7&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Frank%2C+L%2E+R%2E%22&quot;&gt;Frank, L. R.&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Magnetic+Resonance+in+Medicine%22&quot;&gt;Magnetic Resonance in Medicine&lt;/searchLink&gt;. Oct2023, Vol. 90 Issue 4, p1582-1593. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Diffusion+magnetic+resonance+imaging%22&quot;&gt;Diffusion magnetic resonance imaging&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Diffusion+tensor+imaging%22&quot;&gt;Diffusion tensor imaging&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Diffusion+gradients%22&quot;&gt;Diffusion gradients&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Skeletal+muscle%22&quot;&gt;Skeletal muscle&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Diffusion+measurements%22&quot;&gt;Diffusion measurements&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Preliminary study to determine whether double pulsed field gradient (PFG) diffusion MRI is sensitive to key features of muscle microstructure related to function. Methods: The restricted diffusion profile of molecules in models of muscle microstructure derived from histology were systematically simulated using a numerical simulation approach. Diffusion tensor subspace imaging analysis of the diffusion signal was performed, and spherical anisotropy (SA) was calculated for each model. Linear regression was used to determine the predictive capacity of SA on the fiber area, fiber diameter, and surface area to volume ratio of the models. Additionally, a rat model of muscle hypertrophy was scanned using a single PFG and a double PFG pulse sequence, and the restricted diffusion measurements were compared with histological measurements of microstructure. Results: Excellent agreement between SA and muscle fiber area (r2 = 0.71; p &lt; 0.0001), fiber diameter (r2 = 0.83; p &lt; 0.0001), and surface area to volume ratio (r2 = 0.97; p &lt; 0.0001) in simulated models was found. In a scanned rat leg, the distribution of these microstructural features measured from histology was broad and demonstrated that there is a wide variance in the microstructural features observed, similar to the SA distributions. However, the distribution of fractional anisotropy measurements in the same tissue was narrow. Conclusions: This study demonstrates that SA—a scalar value from diffusion tensor subspace imaging analysis—is highly sensitive to muscle microstructural features predictive of function. Furthermore, these techniques and analysis tools can be translated to real experiments in skeletal muscle. The increased dynamic range of SA compared with fractional anisotropy in the same tissue suggests increased sensitivity to detecting changes in tissue microstructure. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=168591188
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.29751
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 1582
    Subjects:
      – SubjectFull: Diffusion magnetic resonance imaging
        Type: general
      – SubjectFull: Diffusion tensor imaging
        Type: general
      – SubjectFull: Diffusion gradients
        Type: general
      – SubjectFull: Skeletal muscle
        Type: general
      – SubjectFull: Diffusion measurements
        Type: general
    Titles:
      – TitleFull: Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Berry, D. B.
      – PersonEntity:
          Name:
            NameFull: Galinsky, V. L.
      – PersonEntity:
          Name:
            NameFull: Hutchinson, E. B.
      – PersonEntity:
          Name:
            NameFull: Galons, J. P.
      – PersonEntity:
          Name:
            NameFull: Ward, S. R.
      – PersonEntity:
          Name:
            NameFull: Frank, L. R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 10
              Text: Oct2023
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 90
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main