Relationship between microvascular status and diagnostic performance of stress dynamic CT perfusion imaging.

Saved in:
Bibliographic Details
Title: Relationship between microvascular status and diagnostic performance of stress dynamic CT perfusion imaging.
Authors: Nagasawa, Naoki1,2 (AUTHOR), Nakamura, Satoshi3 (AUTHOR) s-nakamura@med.mie-u.ac.jp, Ota, Hideki4 (AUTHOR), Ogawa, Ryo5 (AUTHOR), Nakashima, Hitoshi6 (AUTHOR), Hatori, Naoki7 (AUTHOR), Wang, Yining8 (AUTHOR), Kurita, Tairo9 (AUTHOR), Dohi, Kaoru9 (AUTHOR), Sakuma, Hajime10 (AUTHOR), Kitagawa, Kakuya3,11 (AUTHOR)
Source: European Radiology. May2025, Vol. 35 Issue 5, p2855-2865. 11p.
Subjects: Myocardial perfusion imaging, Ischemia, Signal detection, Coronary circulation, Microcirculation disorders, Receiver operating characteristic curves, Arterial stenosis, Coronary arterial radiography
Abstract: Objectives: This study aimed to investigate the relationship between microvascular status in the non-ischemic myocardium and the diagnostic performance of stress dynamic CT perfusion imaging (CTP) in detecting hemodynamically significant stenosis. Materials and methods: This study included 157 patients who underwent coronary computed tomography angiography (CTA), CTP, and invasive coronary angiography (ICA), including fractional flow reserve (FFR). Hemodynamically significant stenosis was defined by FFR and ICA. A relative myocardial blood flow (MBF) for each myocardial segment was normalized to the highest MBF (remote MBF) among 16 segments. Results: The receiver operating characteristic curve analysis for detecting hemodynamically significant stenosis at the vessel level indicated that patients with lower, intermediate, and higher remote MBF had areas under the curve (AUC) of 0.66, 0.70, and 0.80, respectively, for absolute MBF and AUCs of 0.63, 0.70, and 0.83, respectively, for relative MBF. The optimal cut-off values for absolute MBF were proportional to the levels of remote MBFs, while the ones for relative MBF were more consistent across lower to higher remote MBFs. For the patients with high remote MBF, the relative MBF demonstrated a sensitivity of 69%, specificity of 88%, and accuracy of 85% in detecting hemodynamically significant stenosis. Conclusion: The microvascular status in the non-ischemic myocardium influenced the diagnostic performance of dynamic CTP and threshold values of absolute MBFs, suggesting the potential preference for relative MBF over absolute MBF in clinical settings. Dynamic CTP's quantification of MBF offers the benefit of indicating reliability in ischemia detection relative to microvascular status. Key Points: QuestionThe relationship between microvascular status and diagnostic performance of dynamic CTP imaging has not been fully investigated. FindingsThe diagnostic performance of dynamic CTP and threshold values of absolute MBF were impacted by microvascular status. Clinical relevanceThe differences in diagnostic accuracy of dynamic CTP related to varying remote MBF values necessitate a personalized evaluation of myocardial perfusion in dynamic CTP images. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 184707029
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Relationship between microvascular status and diagnostic performance of stress dynamic CT perfusion imaging.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Nagasawa%2C+Naoki%22">Nagasawa, Naoki</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nakamura%2C+Satoshi%22">Nakamura, Satoshi</searchLink><relatesTo>3</relatesTo> (AUTHOR)<i> s-nakamura@med.mie-u.ac.jp</i><br /><searchLink fieldCode="AR" term="%22Ota%2C+Hideki%22">Ota, Hideki</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ogawa%2C+Ryo%22">Ogawa, Ryo</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nakashima%2C+Hitoshi%22">Nakashima, Hitoshi</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hatori%2C+Naoki%22">Hatori, Naoki</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Yining%22">Wang, Yining</searchLink><relatesTo>8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kurita%2C+Tairo%22">Kurita, Tairo</searchLink><relatesTo>9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dohi%2C+Kaoru%22">Dohi, Kaoru</searchLink><relatesTo>9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sakuma%2C+Hajime%22">Sakuma, Hajime</searchLink><relatesTo>10</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kitagawa%2C+Kakuya%22">Kitagawa, Kakuya</searchLink><relatesTo>3,11</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. May2025, Vol. 35 Issue 5, p2855-2865. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Myocardial+perfusion+imaging%22">Myocardial perfusion imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Ischemia%22">Ischemia</searchLink><br /><searchLink fieldCode="DE" term="%22Signal+detection%22">Signal detection</searchLink><br /><searchLink fieldCode="DE" term="%22Coronary+circulation%22">Coronary circulation</searchLink><br /><searchLink fieldCode="DE" term="%22Microcirculation+disorders%22">Microcirculation disorders</searchLink><br /><searchLink fieldCode="DE" term="%22Receiver+operating+characteristic+curves%22">Receiver operating characteristic curves</searchLink><br /><searchLink fieldCode="DE" term="%22Arterial+stenosis%22">Arterial stenosis</searchLink><br /><searchLink fieldCode="DE" term="%22Coronary+arterial+radiography%22">Coronary arterial radiography</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objectives: This study aimed to investigate the relationship between microvascular status in the non-ischemic myocardium and the diagnostic performance of stress dynamic CT perfusion imaging (CTP) in detecting hemodynamically significant stenosis. Materials and methods: This study included 157 patients who underwent coronary computed tomography angiography (CTA), CTP, and invasive coronary angiography (ICA), including fractional flow reserve (FFR). Hemodynamically significant stenosis was defined by FFR and ICA. A relative myocardial blood flow (MBF) for each myocardial segment was normalized to the highest MBF (remote MBF) among 16 segments. Results: The receiver operating characteristic curve analysis for detecting hemodynamically significant stenosis at the vessel level indicated that patients with lower, intermediate, and higher remote MBF had areas under the curve (AUC) of 0.66, 0.70, and 0.80, respectively, for absolute MBF and AUCs of 0.63, 0.70, and 0.83, respectively, for relative MBF. The optimal cut-off values for absolute MBF were proportional to the levels of remote MBFs, while the ones for relative MBF were more consistent across lower to higher remote MBFs. For the patients with high remote MBF, the relative MBF demonstrated a sensitivity of 69%, specificity of 88%, and accuracy of 85% in detecting hemodynamically significant stenosis. Conclusion: The microvascular status in the non-ischemic myocardium influenced the diagnostic performance of dynamic CTP and threshold values of absolute MBFs, suggesting the potential preference for relative MBF over absolute MBF in clinical settings. Dynamic CTP's quantification of MBF offers the benefit of indicating reliability in ischemia detection relative to microvascular status. Key Points: QuestionThe relationship between microvascular status and diagnostic performance of dynamic CTP imaging has not been fully investigated. FindingsThe diagnostic performance of dynamic CTP and threshold values of absolute MBF were impacted by microvascular status. Clinical relevanceThe differences in diagnostic accuracy of dynamic CTP related to varying remote MBF values necessitate a personalized evaluation of myocardial perfusion in dynamic CTP images. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=184707029
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-024-11136-1
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 2855
    Subjects:
      – SubjectFull: Myocardial perfusion imaging
        Type: general
      – SubjectFull: Ischemia
        Type: general
      – SubjectFull: Signal detection
        Type: general
      – SubjectFull: Coronary circulation
        Type: general
      – SubjectFull: Microcirculation disorders
        Type: general
      – SubjectFull: Receiver operating characteristic curves
        Type: general
      – SubjectFull: Arterial stenosis
        Type: general
      – SubjectFull: Coronary arterial radiography
        Type: general
    Titles:
      – TitleFull: Relationship between microvascular status and diagnostic performance of stress dynamic CT perfusion imaging.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Nagasawa, Naoki
      – PersonEntity:
          Name:
            NameFull: Nakamura, Satoshi
      – PersonEntity:
          Name:
            NameFull: Ota, Hideki
      – PersonEntity:
          Name:
            NameFull: Ogawa, Ryo
      – PersonEntity:
          Name:
            NameFull: Nakashima, Hitoshi
      – PersonEntity:
          Name:
            NameFull: Hatori, Naoki
      – PersonEntity:
          Name:
            NameFull: Wang, Yining
      – PersonEntity:
          Name:
            NameFull: Kurita, Tairo
      – PersonEntity:
          Name:
            NameFull: Dohi, Kaoru
      – PersonEntity:
          Name:
            NameFull: Sakuma, Hajime
      – PersonEntity:
          Name:
            NameFull: Kitagawa, Kakuya
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2025
              Type: published
              Y: 2025
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 35
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1