Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system.

Saved in:
Bibliographic Details
Title: Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system.
Authors: Srilakshmi, Koganti1 (AUTHOR), Gummadi, Srinivasa Rao2 (AUTHOR), Valluri, Nagaraju3 (AUTHOR), Balachandran, Praveen Kumar4,5 (AUTHOR), Sangeetha, Kannan6,7 (AUTHOR) sangeethak@kdu.edu.et
Source: Energy Exploration & Exploitation. Mar2026, Vol. 44 Issue 2, p923-945. 23p.
Subjects: Power supply quality, Metaheuristic algorithms, Clean energy investment, Fuzzy control systems, Hydrogen as fuel, PID controllers, Adaptive control systems
Abstract: The incorporation of green energy sources into the network, along with the introduction of power electrical devices to regulate loads that are not linear, has significantly influenced power quality (PQ). Nevertheless, PQ is the primary challenge when integrating inconsistent power from renewable sources. Here, the reduced switch converter is selected for the Unified Power Quality Conditioner (UPQC) that is incorporated with the Solar PV Generation System (SPVGS), hydrogen Fuel cell (FC), and Battery Energy Storage Systems (BESS) to handle PQ problems effectively. This paper suggests a hybrid scheme that has the advantageous characteristics of a neural network controller (NNC), Proportional integral derivative controller (PIDC) and Fuzzy logic controller (FLC). NNC with Synchronous reference frame theory (dq) is adopted to generate the reference signals. Additionally, a meta-heuristic-based chimp algorithm (ChOA) is adapted to design the optimized FLC-PIDC hybrid controller for regulating the DC Link voltage (DLV), resistance, inductance, and capacitance variables of filters, proportional integral controller (PIC) gain values of FC and BESS. The primary goal of the suggested approach is to maintain a stable DLV despite fluctuations in both load and SPVGS. The system also seeks to reduce fluctuations in the load voltage and supply current, as well as to reduce sag, interruption, swell, and imbalances caused by variations in the source voltage. Testing the developed mode with four case studies each with a load like nonlinear, balanced, and unbalanced and grid voltage variations with variable irradiation was done to assess its performance. On the other hand, to validate the proposed technique the comparison analysis is conducted using conventional PIC. The proposed approach effectively decreases the total harmonic distortion (THD) to 2.30%, 2.63%, 2.79%, and 2.64%. These values are notably lower than those achieved by other methods in the literature. [ABSTRACT FROM AUTHOR]
Copyright of Energy Exploration & Exploitation is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 192043507
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Srilakshmi%2C+Koganti%22">Srilakshmi, Koganti</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gummadi%2C+Srinivasa+Rao%22">Gummadi, Srinivasa Rao</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Valluri%2C+Nagaraju%22">Valluri, Nagaraju</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Balachandran%2C+Praveen+Kumar%22">Balachandran, Praveen Kumar</searchLink><relatesTo>4,5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sangeetha%2C+Kannan%22">Sangeetha, Kannan</searchLink><relatesTo>6,7</relatesTo> (AUTHOR)<i> sangeethak@kdu.edu.et</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Energy+Exploration+%26+Exploitation%22">Energy Exploration & Exploitation</searchLink>. Mar2026, Vol. 44 Issue 2, p923-945. 23p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Power+supply+quality%22">Power supply quality</searchLink><br /><searchLink fieldCode="DE" term="%22Metaheuristic+algorithms%22">Metaheuristic algorithms</searchLink><br /><searchLink fieldCode="DE" term="%22Clean+energy+investment%22">Clean energy investment</searchLink><br /><searchLink fieldCode="DE" term="%22Fuzzy+control+systems%22">Fuzzy control systems</searchLink><br /><searchLink fieldCode="DE" term="%22Hydrogen+as+fuel%22">Hydrogen as fuel</searchLink><br /><searchLink fieldCode="DE" term="%22PID+controllers%22">PID controllers</searchLink><br /><searchLink fieldCode="DE" term="%22Adaptive+control+systems%22">Adaptive control systems</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The incorporation of green energy sources into the network, along with the introduction of power electrical devices to regulate loads that are not linear, has significantly influenced power quality (PQ). Nevertheless, PQ is the primary challenge when integrating inconsistent power from renewable sources. Here, the reduced switch converter is selected for the Unified Power Quality Conditioner (UPQC) that is incorporated with the Solar PV Generation System (SPVGS), hydrogen Fuel cell (FC), and Battery Energy Storage Systems (BESS) to handle PQ problems effectively. This paper suggests a hybrid scheme that has the advantageous characteristics of a neural network controller (NNC), Proportional integral derivative controller (PIDC) and Fuzzy logic controller (FLC). NNC with Synchronous reference frame theory (dq) is adopted to generate the reference signals. Additionally, a meta-heuristic-based chimp algorithm (ChOA) is adapted to design the optimized FLC-PIDC hybrid controller for regulating the DC Link voltage (DLV), resistance, inductance, and capacitance variables of filters, proportional integral controller (PIC) gain values of FC and BESS. The primary goal of the suggested approach is to maintain a stable DLV despite fluctuations in both load and SPVGS. The system also seeks to reduce fluctuations in the load voltage and supply current, as well as to reduce sag, interruption, swell, and imbalances caused by variations in the source voltage. Testing the developed mode with four case studies each with a load like nonlinear, balanced, and unbalanced and grid voltage variations with variable irradiation was done to assess its performance. On the other hand, to validate the proposed technique the comparison analysis is conducted using conventional PIC. The proposed approach effectively decreases the total harmonic distortion (THD) to 2.30%, 2.63%, 2.79%, and 2.64%. These values are notably lower than those achieved by other methods in the literature. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Energy Exploration & Exploitation is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=192043507
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1177/01445987251390554
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 23
        StartPage: 923
    Subjects:
      – SubjectFull: Power supply quality
        Type: general
      – SubjectFull: Metaheuristic algorithms
        Type: general
      – SubjectFull: Clean energy investment
        Type: general
      – SubjectFull: Fuzzy control systems
        Type: general
      – SubjectFull: Hydrogen as fuel
        Type: general
      – SubjectFull: PID controllers
        Type: general
      – SubjectFull: Adaptive control systems
        Type: general
    Titles:
      – TitleFull: Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Srilakshmi, Koganti
      – PersonEntity:
          Name:
            NameFull: Gummadi, Srinivasa Rao
      – PersonEntity:
          Name:
            NameFull: Valluri, Nagaraju
      – PersonEntity:
          Name:
            NameFull: Balachandran, Praveen Kumar
      – PersonEntity:
          Name:
            NameFull: Sangeetha, Kannan
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 01445987
          Numbering:
            – Type: volume
              Value: 44
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Energy Exploration & Exploitation
              Type: main
ResultId 1