Coherence evaluation and first demonstration of multi‐contrast X‐ray computed tomography on NanoTerasu BL09W with an X‐ray Talbot interferometer.
Saved in:
| Title: | Coherence evaluation and first demonstration of multi‐contrast X‐ray computed tomography on NanoTerasu BL09W with an X‐ray Talbot interferometer. |
|---|---|
| Authors: | Ueda, Ryosuke1 (AUTHOR) ryosuke.ueda.a7@tohoku.ac.jp, Liang, Xiaoyu2 (AUTHOR), Kamezawa, Chika2 (AUTHOR), Sumiishi, Hiroki3 (AUTHOR), Bishago, Yui3 (AUTHOR), Nishio, Takeyasu3 (AUTHOR), Yoshida, Junya1 (AUTHOR), Daimon, Masaharu4 (AUTHOR), Hiramoto, Shozo4 (AUTHOR), Voegeli, Wolfgang5 (AUTHOR), Shirasawa, Tetsuroh6 (AUTHOR), Vagovič, Patrik7,8 (AUTHOR), Yamane, Hiroyuki4 (AUTHOR), Nakamura, Tetsuya1,4 (AUTHOR), Yashiro, Wataru1,2,3,9 (AUTHOR) wataru.yashiro.a2@tohoku.ac.jp |
| Source: | Journal of Synchrotron Radiation. Mar2026, Vol. 33 Issue 2, p481-488. 8p. |
| Subjects: | X-ray imaging, Interferometers, Diffraction patterns, Coherence (Physics), Tohoku University, Synchrotron radiation sources, Computed tomography |
| Abstract: | We report on the coherence evaluation of the beamline BL09W at NanoTerasu (Tohoku University, Japan) and demonstrate X‐ray multi‐contrast imaging using an X‐ray Talbot interferometer. Fringe visibility was measured in both the horizontal and vertical directions and analyzed to estimate the effective source size of the X‐ray beam. The estimated source size in the horizontal direction was consistent with the design specification, confirming the validity of the measurements. In the vertical direction, the high visibility, exceeding 70%, indicates the remarkably high spatial coherence of the source. Multi‐contrast computed tomography was successfully performed, simultaneously reconstructing absorption, phase and small‐angle scattering contrasts. These results establish BL09W as a versatile beamline for coherence‐based X‐ray imaging. [ABSTRACT FROM AUTHOR] |
| Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 192092555 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Coherence evaluation and first demonstration of multi‐contrast X‐ray computed tomography on NanoTerasu BL09W with an X‐ray Talbot interferometer. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Ueda%2C+Ryosuke%22">Ueda, Ryosuke</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> ryosuke.ueda.a7@tohoku.ac.jp</i><br /><searchLink fieldCode="AR" term="%22Liang%2C+Xiaoyu%22">Liang, Xiaoyu</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kamezawa%2C+Chika%22">Kamezawa, Chika</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sumiishi%2C+Hiroki%22">Sumiishi, Hiroki</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bishago%2C+Yui%22">Bishago, Yui</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nishio%2C+Takeyasu%22">Nishio, Takeyasu</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yoshida%2C+Junya%22">Yoshida, Junya</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Daimon%2C+Masaharu%22">Daimon, Masaharu</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hiramoto%2C+Shozo%22">Hiramoto, Shozo</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Voegeli%2C+Wolfgang%22">Voegeli, Wolfgang</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Shirasawa%2C+Tetsuroh%22">Shirasawa, Tetsuroh</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Vagovič%2C+Patrik%22">Vagovič, Patrik</searchLink><relatesTo>7,8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yamane%2C+Hiroyuki%22">Yamane, Hiroyuki</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nakamura%2C+Tetsuya%22">Nakamura, Tetsuya</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yashiro%2C+Wataru%22">Yashiro, Wataru</searchLink><relatesTo>1,2,3,9</relatesTo> (AUTHOR)<i> wataru.yashiro.a2@tohoku.ac.jp</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Synchrotron+Radiation%22">Journal of Synchrotron Radiation</searchLink>. Mar2026, Vol. 33 Issue 2, p481-488. 8p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22X-ray+imaging%22">X-ray imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Interferometers%22">Interferometers</searchLink><br /><searchLink fieldCode="DE" term="%22Diffraction+patterns%22">Diffraction patterns</searchLink><br /><searchLink fieldCode="DE" term="%22Coherence+%28Physics%29%22">Coherence (Physics)</searchLink><br /><searchLink fieldCode="DE" term="%22Tohoku+University%22">Tohoku University</searchLink><br /><searchLink fieldCode="DE" term="%22Synchrotron+radiation+sources%22">Synchrotron radiation sources</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: We report on the coherence evaluation of the beamline BL09W at NanoTerasu (Tohoku University, Japan) and demonstrate X‐ray multi‐contrast imaging using an X‐ray Talbot interferometer. Fringe visibility was measured in both the horizontal and vertical directions and analyzed to estimate the effective source size of the X‐ray beam. The estimated source size in the horizontal direction was consistent with the design specification, confirming the validity of the measurements. In the vertical direction, the high visibility, exceeding 70%, indicates the remarkably high spatial coherence of the source. Multi‐contrast computed tomography was successfully performed, simultaneously reconstructing absorption, phase and small‐angle scattering contrasts. These results establish BL09W as a versatile beamline for coherence‐based X‐ray imaging. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=192092555 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1107/S1600577526000512 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 8 StartPage: 481 Subjects: – SubjectFull: X-ray imaging Type: general – SubjectFull: Interferometers Type: general – SubjectFull: Diffraction patterns Type: general – SubjectFull: Coherence (Physics) Type: general – SubjectFull: Tohoku University Type: general – SubjectFull: Synchrotron radiation sources Type: general – SubjectFull: Computed tomography Type: general Titles: – TitleFull: Coherence evaluation and first demonstration of multi‐contrast X‐ray computed tomography on NanoTerasu BL09W with an X‐ray Talbot interferometer. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Ueda, Ryosuke – PersonEntity: Name: NameFull: Liang, Xiaoyu – PersonEntity: Name: NameFull: Kamezawa, Chika – PersonEntity: Name: NameFull: Sumiishi, Hiroki – PersonEntity: Name: NameFull: Bishago, Yui – PersonEntity: Name: NameFull: Nishio, Takeyasu – PersonEntity: Name: NameFull: Yoshida, Junya – PersonEntity: Name: NameFull: Daimon, Masaharu – PersonEntity: Name: NameFull: Hiramoto, Shozo – PersonEntity: Name: NameFull: Voegeli, Wolfgang – PersonEntity: Name: NameFull: Shirasawa, Tetsuroh – PersonEntity: Name: NameFull: Vagovič, Patrik – PersonEntity: Name: NameFull: Yamane, Hiroyuki – PersonEntity: Name: NameFull: Nakamura, Tetsuya – PersonEntity: Name: NameFull: Yashiro, Wataru IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 09090495 Numbering: – Type: volume Value: 33 – Type: issue Value: 2 Titles: – TitleFull: Journal of Synchrotron Radiation Type: main |
| ResultId | 1 |