Disinfecting the Coquitlam Water Supply: Ozone and UV Disinfection.

Saved in:
Bibliographic Details
Title: Disinfecting the Coquitlam Water Supply: Ozone and UV Disinfection.
Authors: Landis, Heather1 (AUTHOR) landish@bv.com, Neemann, Jeff1 (AUTHOR), Hulsey, Bob1 (AUTHOR), Fiorante, Reno2 (AUTHOR), Neden, Doug3 (AUTHOR), Singh, Inder3 (AUTHOR)
Source: Ozone: Science & Engineering. Aug2007, Vol. 29 Issue 4, p287-290. 4p. 4 Charts, 2 Graphs.
Subjects: Ozone, Scales (Weighing instruments), Water districts, Water supply, Filters & filtration, Management
Geographic Terms: Coquitlam (B.C.), British Columbia, Canada
Abstract: The Greater Vancouver Water District (GVWD) is upgrading its unfiltered Coquitlam water treatment system to meet the updated Health Canada guidelines for providing 3-log reduction or inactivation of Cryptosporidium and Giardia. The existing Coquitlam system, which is designed for peak flows of 1200 ML/d (317 mgd), includes an ozonation facility providing 3 log Giardia inactivation, and a chlorination/corrosion control facility. To meet Health Canada guidelines, a UV disinfection facility will be constructed, which will provide 3-log inactivation of Cryptosporidium and Giardia, and the ozone dosage will be increased to reduce THM and HAA precursors as well as improve UV transmittance. This paper will focus on the conceptual design of the Coquitlam system and the preliminary bench-scale studies that were completed for GVWD as part of the predesign phase of the project. [ABSTRACT FROM AUTHOR]
Copyright of Ozone: Science & Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 26099548
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Disinfecting the Coquitlam Water Supply: Ozone and UV Disinfection.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Landis%2C+Heather%22">Landis, Heather</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> landish@bv.com</i><br /><searchLink fieldCode="AR" term="%22Neemann%2C+Jeff%22">Neemann, Jeff</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hulsey%2C+Bob%22">Hulsey, Bob</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Fiorante%2C+Reno%22">Fiorante, Reno</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Neden%2C+Doug%22">Neden, Doug</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Singh%2C+Inder%22">Singh, Inder</searchLink><relatesTo>3</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Ozone%3A+Science+%26+Engineering%22">Ozone: Science & Engineering</searchLink>. Aug2007, Vol. 29 Issue 4, p287-290. 4p. 4 Charts, 2 Graphs.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Ozone%22">Ozone</searchLink><br /><searchLink fieldCode="DE" term="%22Scales+%28Weighing+instruments%29%22">Scales (Weighing instruments)</searchLink><br /><searchLink fieldCode="DE" term="%22Water+districts%22">Water districts</searchLink><br /><searchLink fieldCode="DE" term="%22Water+supply%22">Water supply</searchLink><br /><searchLink fieldCode="DE" term="%22Filters+%26+filtration%22">Filters & filtration</searchLink><br /><searchLink fieldCode="DE" term="%22Management%22">Management</searchLink>
– Name: SubjectGeographic
  Label: Geographic Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Coquitlam+%28B%2EC%2E%29%22">Coquitlam (B.C.)</searchLink><br /><searchLink fieldCode="DE" term="%22British+Columbia%22">British Columbia</searchLink><br /><searchLink fieldCode="DE" term="%22Canada%22">Canada</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The Greater Vancouver Water District (GVWD) is upgrading its unfiltered Coquitlam water treatment system to meet the updated Health Canada guidelines for providing 3-log reduction or inactivation of Cryptosporidium and Giardia. The existing Coquitlam system, which is designed for peak flows of 1200 ML/d (317 mgd), includes an ozonation facility providing 3 log Giardia inactivation, and a chlorination/corrosion control facility. To meet Health Canada guidelines, a UV disinfection facility will be constructed, which will provide 3-log inactivation of Cryptosporidium and Giardia, and the ozone dosage will be increased to reduce THM and HAA precursors as well as improve UV transmittance. This paper will focus on the conceptual design of the Coquitlam system and the preliminary bench-scale studies that were completed for GVWD as part of the predesign phase of the project. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Ozone: Science & Engineering is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=26099548
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1080/01919510701460087
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 287
    Subjects:
      – SubjectFull: Ozone
        Type: general
      – SubjectFull: Scales (Weighing instruments)
        Type: general
      – SubjectFull: Water districts
        Type: general
      – SubjectFull: Water supply
        Type: general
      – SubjectFull: Filters & filtration
        Type: general
      – SubjectFull: Management
        Type: general
      – SubjectFull: Coquitlam (B.C.)
        Type: general
      – SubjectFull: British Columbia
        Type: general
      – SubjectFull: Canada
        Type: general
    Titles:
      – TitleFull: Disinfecting the Coquitlam Water Supply: Ozone and UV Disinfection.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Landis, Heather
      – PersonEntity:
          Name:
            NameFull: Neemann, Jeff
      – PersonEntity:
          Name:
            NameFull: Hulsey, Bob
      – PersonEntity:
          Name:
            NameFull: Fiorante, Reno
      – PersonEntity:
          Name:
            NameFull: Neden, Doug
      – PersonEntity:
          Name:
            NameFull: Singh, Inder
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 08
              Text: Aug2007
              Type: published
              Y: 2007
          Identifiers:
            – Type: issn-print
              Value: 01919512
          Numbering:
            – Type: volume
              Value: 29
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Ozone: Science & Engineering
              Type: main