A national survey on radon concentration in underground inspection rooms and in buildings of a telephone company: methods and first results
Saved in:
| Title: | A national survey on radon concentration in underground inspection rooms and in buildings of a telephone company: methods and first results |
|---|---|
| Authors: | Carelli, V.1 vinicio.carelli@telecomitalia.it, Bianco, V.1, Cordedda, C.1, Ferrigno, G.2, Carpentieri, C.2, Bochicchio, F.2 |
| Source: | Radiation Measurements. Oct2009, Vol. 44 Issue 9/10, p1058-1063. 6p. |
| Subjects: | Radiation measurements, Radon, Telephone companies, Nuclear track detectors, Inspection & review |
| Abstract: | Abstract: A national survey has been carried out to measure radon concentration in a large sample of Telecom-Italia small underground inspection rooms, which form a particularly dense net in urban areas. Measuring radon in such underground places is interesting both for a possible contribution to radon mapping activities and to evaluate workers exposures. Radon concentration was also measured in Telecom buildings (i.e. buildings housing plant equipment, including telephone switches, often also offices, etc.) close and partially connected to the selected inspection rooms. The methodology and the first results of the survey related to the first year of measurements, for a total of 1438 inspection rooms and 1414 Telecom buildings, are reported. Radon concentration was measured with passive devices containing CR-39 detectors for about 12 consecutive months, in order to average seasonal variations. In underground inspection rooms, measured radon concentration reached values up to about 44,000Bq/m3, with a regional median ranging from about 90Bq/m3 up to about 1600Bq/m3. In Telecom buildings, the regional median concentration ranged from 13Bq/m3 to 174Bq/m3. These results show that radon concentration in underground inspection rooms can reach very high values, whereas medians in monitored buildings are generally lower than those measured in dwellings in a representative national survey. [Copyright &y& Elsevier] |
| Copyright of Radiation Measurements is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 45659591 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A national survey on radon concentration in underground inspection rooms and in buildings of a telephone company: methods and first results – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Carelli%2C+V%2E%22">Carelli, V.</searchLink><relatesTo>1</relatesTo><i> vinicio.carelli@telecomitalia.it</i><br /><searchLink fieldCode="AR" term="%22Bianco%2C+V%2E%22">Bianco, V.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Cordedda%2C+C%2E%22">Cordedda, C.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ferrigno%2C+G%2E%22">Ferrigno, G.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Carpentieri%2C+C%2E%22">Carpentieri, C.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Bochicchio%2C+F%2E%22">Bochicchio, F.</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Radiation+Measurements%22">Radiation Measurements</searchLink>. Oct2009, Vol. 44 Issue 9/10, p1058-1063. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Radiation+measurements%22">Radiation measurements</searchLink><br /><searchLink fieldCode="DE" term="%22Radon%22">Radon</searchLink><br /><searchLink fieldCode="DE" term="%22Telephone+companies%22">Telephone companies</searchLink><br /><searchLink fieldCode="DE" term="%22Nuclear+track+detectors%22">Nuclear track detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Inspection+%26+review%22">Inspection & review</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: A national survey has been carried out to measure radon concentration in a large sample of Telecom-Italia small underground inspection rooms, which form a particularly dense net in urban areas. Measuring radon in such underground places is interesting both for a possible contribution to radon mapping activities and to evaluate workers exposures. Radon concentration was also measured in Telecom buildings (i.e. buildings housing plant equipment, including telephone switches, often also offices, etc.) close and partially connected to the selected inspection rooms. The methodology and the first results of the survey related to the first year of measurements, for a total of 1438 inspection rooms and 1414 Telecom buildings, are reported. Radon concentration was measured with passive devices containing CR-39 detectors for about 12 consecutive months, in order to average seasonal variations. In underground inspection rooms, measured radon concentration reached values up to about 44,000Bq/m3, with a regional median ranging from about 90Bq/m3 up to about 1600Bq/m3. In Telecom buildings, the regional median concentration ranged from 13Bq/m3 to 174Bq/m3. These results show that radon concentration in underground inspection rooms can reach very high values, whereas medians in monitored buildings are generally lower than those measured in dwellings in a representative national survey. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Radiation Measurements is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=45659591 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.radmeas.2009.10.085 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 1058 Subjects: – SubjectFull: Radiation measurements Type: general – SubjectFull: Radon Type: general – SubjectFull: Telephone companies Type: general – SubjectFull: Nuclear track detectors Type: general – SubjectFull: Inspection & review Type: general Titles: – TitleFull: A national survey on radon concentration in underground inspection rooms and in buildings of a telephone company: methods and first results Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Carelli, V. – PersonEntity: Name: NameFull: Bianco, V. – PersonEntity: Name: NameFull: Cordedda, C. – PersonEntity: Name: NameFull: Ferrigno, G. – PersonEntity: Name: NameFull: Carpentieri, C. – PersonEntity: Name: NameFull: Bochicchio, F. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2009 Type: published Y: 2009 Identifiers: – Type: issn-print Value: 13504487 Numbering: – Type: volume Value: 44 – Type: issue Value: 9/10 Titles: – TitleFull: Radiation Measurements Type: main |
| ResultId | 1 |