Monte Carlo study of a 3D Compton imaging device with GEANT4

Saved in:
Bibliographic Details
Title: Monte Carlo study of a 3D Compton imaging device with GEANT4
Authors: Lenti, M.1 lenti@fi.infn.it, Veltri, M.1,2 michele.veltri@uniurb.it
Source: Nuclear Instruments & Methods in Physics Research Section A. Oct2011, Vol. 654 Issue 1, p560-568. 9p.
Subjects: Photon scattering, Monte Carlo method, Imaging systems, Compton effect, Nondestructive testing, Germanium diodes, Gamma rays, Brain imaging
Abstract: Abstract: In this paper we investigate, with a detailed Monte Carlo simulation based on Geant4, the novel approach of Lenti (2008) to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used to illuminate the object to be imaged and the photons Compton scattered are detected by means of a surrounding germanium strip detector. The impact position and the energy of the photons are measured with high precision and the scattering position along the beam axis is calculated. We study as an application of this technique the case of brain imaging but the results can be applied as well to situations where a lighter object, with localized variations of density, is embedded in a denser container. We report here the attainable sensitivity in the detection of density variations as a function of the beam energy, the depth inside the object and size and density of the inclusions. Using a 600keV gamma beam, for an inclusion with a density increase of 30% with respect to the surrounding tissue and thickness along the beam of 5mm, we obtain at midbrain position a resolution of about 2mm and a contrast of 12%. In addition the simulation indicates that for the same gamma beam energy a complete brain scan would result in an effective dose of about 1mSv. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 65869880
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Monte Carlo study of a 3D Compton imaging device with GEANT4
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Lenti%2C+M%2E%22">Lenti, M.</searchLink><relatesTo>1</relatesTo><i> lenti@fi.infn.it</i><br /><searchLink fieldCode="AR" term="%22Veltri%2C+M%2E%22">Veltri, M.</searchLink><relatesTo>1,2</relatesTo><i> michele.veltri@uniurb.it</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Oct2011, Vol. 654 Issue 1, p560-568. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Photon+scattering%22">Photon scattering</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink><br /><searchLink fieldCode="DE" term="%22Imaging+systems%22">Imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Compton+effect%22">Compton effect</searchLink><br /><searchLink fieldCode="DE" term="%22Nondestructive+testing%22">Nondestructive testing</searchLink><br /><searchLink fieldCode="DE" term="%22Germanium+diodes%22">Germanium diodes</searchLink><br /><searchLink fieldCode="DE" term="%22Gamma+rays%22">Gamma rays</searchLink><br /><searchLink fieldCode="DE" term="%22Brain+imaging%22">Brain imaging</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: In this paper we investigate, with a detailed Monte Carlo simulation based on Geant4, the novel approach of Lenti (2008) to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used to illuminate the object to be imaged and the photons Compton scattered are detected by means of a surrounding germanium strip detector. The impact position and the energy of the photons are measured with high precision and the scattering position along the beam axis is calculated. We study as an application of this technique the case of brain imaging but the results can be applied as well to situations where a lighter object, with localized variations of density, is embedded in a denser container. We report here the attainable sensitivity in the detection of density variations as a function of the beam energy, the depth inside the object and size and density of the inclusions. Using a 600keV gamma beam, for an inclusion with a density increase of 30% with respect to the surrounding tissue and thickness along the beam of 5mm, we obtain at midbrain position a resolution of about 2mm and a contrast of 12%. In addition the simulation indicates that for the same gamma beam energy a complete brain scan would result in an effective dose of about 1mSv. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=65869880
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.nima.2011.06.060
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 560
    Subjects:
      – SubjectFull: Photon scattering
        Type: general
      – SubjectFull: Monte Carlo method
        Type: general
      – SubjectFull: Imaging systems
        Type: general
      – SubjectFull: Compton effect
        Type: general
      – SubjectFull: Nondestructive testing
        Type: general
      – SubjectFull: Germanium diodes
        Type: general
      – SubjectFull: Gamma rays
        Type: general
      – SubjectFull: Brain imaging
        Type: general
    Titles:
      – TitleFull: Monte Carlo study of a 3D Compton imaging device with GEANT4
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Lenti, M.
      – PersonEntity:
          Name:
            NameFull: Veltri, M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 21
              M: 10
              Text: Oct2011
              Type: published
              Y: 2011
          Identifiers:
            – Type: issn-print
              Value: 01689002
          Numbering:
            – Type: volume
              Value: 654
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Nuclear Instruments & Methods in Physics Research Section A
              Type: main
ResultId 1