An evaluation of data-driven motion estimation in comparison to the usage of external-surrogates in cardiac SPECT imaging.

Saved in:
Bibliographic Details
Title: An evaluation of data-driven motion estimation in comparison to the usage of external-surrogates in cardiac SPECT imaging.
Authors: Mukherjee, Joyeeta Mitra1 joyeeta.mitra@umassmed.edu, Hutton, Brian F2,3, Johnson, Karen L1, Pretorius, P Hendrik1, King, Michael A1
Source: Physics in Medicine & Biology. 11/7/2013, Vol. 58 Issue 21, p7625-7646. 22p.
Subjects: Motion estimation (Signal processing), Photon emission, Computed tomography, Attenuation (Physics), Entropy, Monte Carlo method
Abstract: Motion estimation methods in single photon emission computed tomography (SPECT) can be classified into methods which depend on just the emission data (data-driven), or those that use some other source of information such as an external surrogate. The surrogate-based methods estimate the motion exhibited externally which may not correlate exactly with the movement of organs inside the body. The accuracy of data-driven strategies on the other hand is affected by the type and timing of motion occurrence during acquisition, the source distribution, and various degrading factors such as attenuation, scatter, and system spatial resolution. The goal of this paper is to investigate the performance of two data-driven motion estimation schemes based on the rigid-body registration of projections of motion-transformed source distributions to the acquired projection data for cardiac SPECT studies. Comparison is also made of six intensity based registration metrics to an external surrogate-based method. In the data-driven schemes, a partially reconstructed heart is used as the initial source distribution. The partially-reconstructed heart has inaccuracies due to limited angle artifacts resulting from using only a part of the SPECT projections acquired while the patient maintained the same pose. The performance of different cost functions in quantifying consistency with the SPECT projection data in the data-driven schemes was compared for clinically realistic patient motion occurring as discrete pose changes, one or two times during acquisition. The six intensity-based metrics studied were mean-squared difference, mutual information, normalized mutual information (NMI), pattern intensity (PI), normalized cross-correlation and entropy of the difference. Quantitative and qualitative analysis of the performance is reported using Monte-Carlo simulations of a realistic heart phantom including degradation factors such as attenuation, scatter and system spatial resolution. Further the visual appearance of motion-corrected images using data-driven motion estimates was compared to that obtained using the external motion-tracking system in patient studies. Pattern intensity and normalized mutual information cost functions were observed to have the best performance in terms of lowest average position error and stability with degradation of image quality of the partial reconstruction in simulations. In all patients, the visual quality of PI-based estimation was either significantly better or comparable to NMI-based estimation. Best visual quality was obtained with PI-based estimation in one of the five patient studies, and with external-surrogate based correction in three out of five patients. In the remaining patient study there was little motion and all methods yielded similar visual image quality. [ABSTRACT FROM AUTHOR]
© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 94292115
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: An evaluation of data-driven motion estimation in comparison to the usage of external-surrogates in cardiac SPECT imaging.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Mukherjee%2C+Joyeeta+Mitra%22">Mukherjee, Joyeeta Mitra</searchLink><relatesTo>1</relatesTo><i> joyeeta.mitra@umassmed.edu</i><br /><searchLink fieldCode="AR" term="%22Hutton%2C+Brian+F%22">Hutton, Brian F</searchLink><relatesTo>2,3</relatesTo><br /><searchLink fieldCode="AR" term="%22Johnson%2C+Karen+L%22">Johnson, Karen L</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Pretorius%2C+P+Hendrik%22">Pretorius, P Hendrik</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22King%2C+Michael+A%22">King, Michael A</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Physics+in+Medicine+%26+Biology%22">Physics in Medicine & Biology</searchLink>. 11/7/2013, Vol. 58 Issue 21, p7625-7646. 22p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Motion+estimation+%28Signal+processing%29%22">Motion estimation (Signal processing)</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+emission%22">Photon emission</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Attenuation+%28Physics%29%22">Attenuation (Physics)</searchLink><br /><searchLink fieldCode="DE" term="%22Entropy%22">Entropy</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Motion estimation methods in single photon emission computed tomography (SPECT) can be classified into methods which depend on just the emission data (data-driven), or those that use some other source of information such as an external surrogate. The surrogate-based methods estimate the motion exhibited externally which may not correlate exactly with the movement of organs inside the body. The accuracy of data-driven strategies on the other hand is affected by the type and timing of motion occurrence during acquisition, the source distribution, and various degrading factors such as attenuation, scatter, and system spatial resolution. The goal of this paper is to investigate the performance of two data-driven motion estimation schemes based on the rigid-body registration of projections of motion-transformed source distributions to the acquired projection data for cardiac SPECT studies. Comparison is also made of six intensity based registration metrics to an external surrogate-based method. In the data-driven schemes, a partially reconstructed heart is used as the initial source distribution. The partially-reconstructed heart has inaccuracies due to limited angle artifacts resulting from using only a part of the SPECT projections acquired while the patient maintained the same pose. The performance of different cost functions in quantifying consistency with the SPECT projection data in the data-driven schemes was compared for clinically realistic patient motion occurring as discrete pose changes, one or two times during acquisition. The six intensity-based metrics studied were mean-squared difference, mutual information, normalized mutual information (NMI), pattern intensity (PI), normalized cross-correlation and entropy of the difference. Quantitative and qualitative analysis of the performance is reported using Monte-Carlo simulations of a realistic heart phantom including degradation factors such as attenuation, scatter and system spatial resolution. Further the visual appearance of motion-corrected images using data-driven motion estimates was compared to that obtained using the external motion-tracking system in patient studies. Pattern intensity and normalized mutual information cost functions were observed to have the best performance in terms of lowest average position error and stability with degradation of image quality of the partial reconstruction in simulations. In all patients, the visual quality of PI-based estimation was either significantly better or comparable to NMI-based estimation. Best visual quality was obtained with PI-based estimation in one of the five patient studies, and with external-surrogate based correction in three out of five patients. In the remaining patient study there was little motion and all methods yielded similar visual image quality. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=94292115
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1088/0031-9155/58/21/7625
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 22
        StartPage: 7625
    Subjects:
      – SubjectFull: Motion estimation (Signal processing)
        Type: general
      – SubjectFull: Photon emission
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Attenuation (Physics)
        Type: general
      – SubjectFull: Entropy
        Type: general
      – SubjectFull: Monte Carlo method
        Type: general
    Titles:
      – TitleFull: An evaluation of data-driven motion estimation in comparison to the usage of external-surrogates in cardiac SPECT imaging.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Mukherjee, Joyeeta Mitra
      – PersonEntity:
          Name:
            NameFull: Hutton, Brian F
      – PersonEntity:
          Name:
            NameFull: Johnson, Karen L
      – PersonEntity:
          Name:
            NameFull: Pretorius, P Hendrik
      – PersonEntity:
          Name:
            NameFull: King, Michael A
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 07
              M: 11
              Text: 11/7/2013
              Type: published
              Y: 2013
          Identifiers:
            – Type: issn-print
              Value: 00319155
          Numbering:
            – Type: volume
              Value: 58
            – Type: issue
              Value: 21
          Titles:
            – TitleFull: Physics in Medicine & Biology
              Type: main
ResultId 1