| Abstract: | Background: Analytical evaluations of an available system for capillary zone electrophoresis (CZE) of serum protein have been reported. However, data concerning long-term precision and stability of the system, operated under routine conditions, are lacking. We report data from an internal quality control (QC) scheme, obtained over a 1-year period. Methods: Measurements were done with a pair of instruments (Beckman Paragon CZE 2000 system), each equipped with seven capillaries. After preliminary (1 month) assessment of possible inter-capillary and inter-instrument variations, the QC material (a home prepared serum pool stored in the frozen state) was assayed daily over a 1-year period. Results: Maximum inter-capillary and inter-instrument differences were 3.1% and 2.4%. No significant trend was observed for daily values (205 measurements over 1 year); in the same period overall imprecision values (CV) were in the interval 1.2% (albumin) to 3.2–6.1% (globulin zones). Mean monthly imprecision (CV) values were in the interval 1.1% (albumin) to 5.2% (globulin zones). There was no significant trend of monthly means with time. The observed imprecision values were within the biological variation-derived goals for imprecision. Conclusions: It is concluded that the assessed analytical instruments, operated in routine conditions, show long-term stability and imprecision consistent with the clinical use of the results produced. [Copyright &y& Elsevier] |
| Copyright of Clinica Chimica Acta is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 9952070 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Precision and long-term stability of capillary electrophoresis measurement of serum protein zones – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Luraschi%2C+Paola%22">Luraschi, Paola</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Brambilla%2C+Simona%22">Brambilla, Simona</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Infusino%2C+Ilenia%22">Infusino, Ilenia</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Franzini%2C+Carlo%22">Franzini, Carlo</searchLink><relatesTo>2</relatesTo><i> carlo.franzini@unimi.it</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Clinica+Chimica+Acta%22">Clinica Chimica Acta</searchLink>. Jul2003, Vol. 333 Issue 1, p41. 5p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Electrophoresis%22">Electrophoresis</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+proteins%22">Blood proteins</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Background: Analytical evaluations of an available system for capillary zone electrophoresis (CZE) of serum protein have been reported. However, data concerning long-term precision and stability of the system, operated under routine conditions, are lacking. We report data from an internal quality control (QC) scheme, obtained over a 1-year period. Methods: Measurements were done with a pair of instruments (Beckman Paragon CZE 2000 system), each equipped with seven capillaries. After preliminary (1 month) assessment of possible inter-capillary and inter-instrument variations, the QC material (a home prepared serum pool stored in the frozen state) was assayed daily over a 1-year period. Results: Maximum inter-capillary and inter-instrument differences were 3.1% and 2.4%. No significant trend was observed for daily values (205 measurements over 1 year); in the same period overall imprecision values (CV) were in the interval 1.2% (albumin) to 3.2–6.1% (globulin zones). Mean monthly imprecision (CV) values were in the interval 1.1% (albumin) to 5.2% (globulin zones). There was no significant trend of monthly means with time. The observed imprecision values were within the biological variation-derived goals for imprecision. Conclusions: It is concluded that the assessed analytical instruments, operated in routine conditions, show long-term stability and imprecision consistent with the clinical use of the results produced. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Clinica Chimica Acta is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=9952070 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/S0009-8981(03)00163-3 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 5 StartPage: 41 Subjects: – SubjectFull: Electrophoresis Type: general – SubjectFull: Blood proteins Type: general Titles: – TitleFull: Precision and long-term stability of capillary electrophoresis measurement of serum protein zones Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Luraschi, Paola – PersonEntity: Name: NameFull: Brambilla, Simona – PersonEntity: Name: NameFull: Infusino, Ilenia – PersonEntity: Name: NameFull: Franzini, Carlo IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2003 Type: published Y: 2003 Identifiers: – Type: issn-print Value: 00098981 Numbering: – Type: volume Value: 333 – Type: issue Value: 1 Titles: – TitleFull: Clinica Chimica Acta Type: main |
| ResultId | 1 |