Lower Versus Higher Cost Sound Level Meters for the Calibration of Clinical Sound Pressure Level Measurements.

Saved in:
Bibliographic Details
Title: Lower Versus Higher Cost Sound Level Meters for the Calibration of Clinical Sound Pressure Level Measurements.
Authors: Maryn, Youri1,2,3,4 youri.maryn@zas.be, Sismono, Fergio1
Source: American Journal of Speech-Language Pathology. May2026, Vol. 35 Issue 3, p1268-1273. 6p.
Subject Terms: *Audiometry, *Speech evaluation, *Communication, *Comparative studies, Pearson correlation (Statistics), Cost analysis, Descriptive statistics, Physiological aspects of speech, Calibration, Data analysis software, Phonetics, Transducers
Geographic Terms: Belgium
Abstract: Purpose: Clinical measurements of voice/speech sound pressure level (SPL) require calibration. However, relatively expensive sound level meter (SLM) may be required, which can be problematic for clinicians with limited resources. Method: This study therefore compared performance (correlation and error) of 11 lower cost mobile communication device (MCD)-based SLMs (SLMMCD; without or with miniature measurement microphones and dedicated software) with Class 2 SPL measurements. Results: Only three SLMMCDs provided accurate SPL measurements. In four other SLMMCDs, response was nonlinear. Conclusion: SPL measurements with low-cost and MCD-based SLMs can be accurate, but, in this study, only for miniature measurement microphones for which factory-determined correction terms were available. [ABSTRACT FROM AUTHOR]
Copyright of American Journal of Speech-Language Pathology is the property of American Speech-Language-Hearing Association and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Education Research Complete
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: ehh
DbLabel: Education Research Complete
An: 193560225
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Lower Versus Higher Cost Sound Level Meters for the Calibration of Clinical Sound Pressure Level Measurements.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Maryn%2C+Youri%22">Maryn, Youri</searchLink><relatesTo>1,2,3,4</relatesTo><i> youri.maryn@zas.be</i><br /><searchLink fieldCode="AR" term="%22Sismono%2C+Fergio%22">Sismono, Fergio</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22American+Journal+of+Speech-Language+Pathology%22">American Journal of Speech-Language Pathology</searchLink>. May2026, Vol. 35 Issue 3, p1268-1273. 6p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Audiometry%22">Audiometry</searchLink><br />*<searchLink fieldCode="DE" term="%22Speech+evaluation%22">Speech evaluation</searchLink><br />*<searchLink fieldCode="DE" term="%22Communication%22">Communication</searchLink><br />*<searchLink fieldCode="DE" term="%22Comparative+studies%22">Comparative studies</searchLink><br /><searchLink fieldCode="DE" term="%22Pearson+correlation+%28Statistics%29%22">Pearson correlation (Statistics)</searchLink><br /><searchLink fieldCode="DE" term="%22Cost+analysis%22">Cost analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Physiological+aspects+of+speech%22">Physiological aspects of speech</searchLink><br /><searchLink fieldCode="DE" term="%22Calibration%22">Calibration</searchLink><br /><searchLink fieldCode="DE" term="%22Data+analysis+software%22">Data analysis software</searchLink><br /><searchLink fieldCode="DE" term="%22Phonetics%22">Phonetics</searchLink><br /><searchLink fieldCode="DE" term="%22Transducers%22">Transducers</searchLink>
– Name: SubjectGeographic
  Label: Geographic Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Belgium%22">Belgium</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Clinical measurements of voice/speech sound pressure level (SPL) require calibration. However, relatively expensive sound level meter (SLM) may be required, which can be problematic for clinicians with limited resources. Method: This study therefore compared performance (correlation and error) of 11 lower cost mobile communication device (MCD)-based SLMs (SLMMCD; without or with miniature measurement microphones and dedicated software) with Class 2 SPL measurements. Results: Only three SLMMCDs provided accurate SPL measurements. In four other SLMMCDs, response was nonlinear. Conclusion: SPL measurements with low-cost and MCD-based SLMs can be accurate, but, in this study, only for miniature measurement microphones for which factory-determined correction terms were available. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of American Journal of Speech-Language Pathology is the property of American Speech-Language-Hearing Association and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ehh&AN=193560225
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1044/2026_AJSLP-25-00517
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 1268
    Subjects:
      – SubjectFull: Audiometry
        Type: general
      – SubjectFull: Speech evaluation
        Type: general
      – SubjectFull: Communication
        Type: general
      – SubjectFull: Comparative studies
        Type: general
      – SubjectFull: Pearson correlation (Statistics)
        Type: general
      – SubjectFull: Cost analysis
        Type: general
      – SubjectFull: Descriptive statistics
        Type: general
      – SubjectFull: Physiological aspects of speech
        Type: general
      – SubjectFull: Calibration
        Type: general
      – SubjectFull: Data analysis software
        Type: general
      – SubjectFull: Phonetics
        Type: general
      – SubjectFull: Transducers
        Type: general
      – SubjectFull: Belgium
        Type: general
    Titles:
      – TitleFull: Lower Versus Higher Cost Sound Level Meters for the Calibration of Clinical Sound Pressure Level Measurements.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Maryn, Youri
      – PersonEntity:
          Name:
            NameFull: Sismono, Fergio
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Text: May2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 10580360
          Numbering:
            – Type: volume
              Value: 35
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: American Journal of Speech-Language Pathology
              Type: main
ResultId 1