Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers.

Saved in:
Bibliographic Details
Title: Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers.
Authors: Moonkum, Nutthapong1 (AUTHOR), Thawornnittayakul, Aksarapak1 (AUTHOR), Tochaikul, Gunjanaporn1 (AUTHOR) gunjanaporn.t@rsu.ac.th
Source: Radiation & Environmental Biophysics. Mar2026, Vol. 65 Issue 1, p587-596. 10p.
Subject Terms: *Radiation shielding, *Bismuth oxides, *Radiation protection, *Attenuation coefficients, *Epoxy resins, *Cement composites
Abstract: Owing to the use of highly penetrating gamma radiation for medical proposes, radiation shielding is a crucial issue for radiological protection. Lead-free shielding materials are becoming more interesting to solve the disadvantages of lead (i.e., toxicity and heaviness). This study investigates the radiation shielding performance of epoxy resin (ER) and Portland cement (PC) composites enriched with bismuth oxide (Bi2O3) fillers at weight ratios of 20%, 30%, 40%, and 50%, across photon energies ranging from 122 to 662 keV. The results indicate that higher Bi2O3 content enhances the linear attenuation coefficient (0.299 to 1.187 cm− 1), radiation protection efficiency (26 to 99%) and lead-equivalent thickness (0.16 to 2.1 cm), demonstrating improved radiation attenuation ability. The transmission factor (TF) was calculated for four different thicknesses of each composite, showing that thicker samples resulted in lower TF values (0.86%) compared to thinner ones (74.16%). Despite being thicker than the standard lead shielding; the composites are half of the weight. Among all tested samples, the ER/Bi50 composite demonstrated the most effective shielding potential. While no full economic or life cycle assessment was conducted, the use of non-toxic components and reduced weight suggests that ER/Bi50 may offer potential advantages in terms of cost-effectiveness and environmental friendliness. Thus, ER/Bi50 with 4 cm thickness is proposed as a promising lead-free alternative to conventional lead-based shielding materials for gamma ray attenuation in medical applications at energies below 356 keV. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
FullText Text:
  Availability: 0
Header DbId: enr
DbLabel: Energy & Power Source
An: 193393816
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi<subscript>2</subscript>O<subscript>3</subscript> additive fillers.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Moonkum%2C+Nutthapong%22">Moonkum, Nutthapong</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Thawornnittayakul%2C+Aksarapak%22">Thawornnittayakul, Aksarapak</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Tochaikul%2C+Gunjanaporn%22">Tochaikul, Gunjanaporn</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> gunjanaporn.t@rsu.ac.th</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Radiation+%26+Environmental+Biophysics%22">Radiation & Environmental Biophysics</searchLink>. Mar2026, Vol. 65 Issue 1, p587-596. 10p.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Radiation+shielding%22">Radiation shielding</searchLink><br />*<searchLink fieldCode="DE" term="%22Bismuth+oxides%22">Bismuth oxides</searchLink><br />*<searchLink fieldCode="DE" term="%22Radiation+protection%22">Radiation protection</searchLink><br />*<searchLink fieldCode="DE" term="%22Attenuation+coefficients%22">Attenuation coefficients</searchLink><br />*<searchLink fieldCode="DE" term="%22Epoxy+resins%22">Epoxy resins</searchLink><br />*<searchLink fieldCode="DE" term="%22Cement+composites%22">Cement composites</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Owing to the use of highly penetrating gamma radiation for medical proposes, radiation shielding is a crucial issue for radiological protection. Lead-free shielding materials are becoming more interesting to solve the disadvantages of lead (i.e., toxicity and heaviness). This study investigates the radiation shielding performance of epoxy resin (ER) and Portland cement (PC) composites enriched with bismuth oxide (Bi2O3) fillers at weight ratios of 20%, 30%, 40%, and 50%, across photon energies ranging from 122 to 662 keV. The results indicate that higher Bi2O3 content enhances the linear attenuation coefficient (0.299 to 1.187 cm− 1), radiation protection efficiency (26 to 99%) and lead-equivalent thickness (0.16 to 2.1 cm), demonstrating improved radiation attenuation ability. The transmission factor (TF) was calculated for four different thicknesses of each composite, showing that thicker samples resulted in lower TF values (0.86%) compared to thinner ones (74.16%). Despite being thicker than the standard lead shielding; the composites are half of the weight. Among all tested samples, the ER/Bi50 composite demonstrated the most effective shielding potential. While no full economic or life cycle assessment was conducted, the use of non-toxic components and reduced weight suggests that ER/Bi50 may offer potential advantages in terms of cost-effectiveness and environmental friendliness. Thus, ER/Bi50 with 4 cm thickness is proposed as a promising lead-free alternative to conventional lead-based shielding materials for gamma ray attenuation in medical applications at energies below 356 keV. [ABSTRACT FROM AUTHOR]
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=enr&AN=193393816
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00411-025-01166-8
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 587
    Subjects:
      – SubjectFull: Radiation shielding
        Type: general
      – SubjectFull: Bismuth oxides
        Type: general
      – SubjectFull: Radiation protection
        Type: general
      – SubjectFull: Attenuation coefficients
        Type: general
      – SubjectFull: Epoxy resins
        Type: general
      – SubjectFull: Cement composites
        Type: general
    Titles:
      – TitleFull: Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Moonkum, Nutthapong
      – PersonEntity:
          Name:
            NameFull: Thawornnittayakul, Aksarapak
      – PersonEntity:
          Name:
            NameFull: Tochaikul, Gunjanaporn
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 03
              Text: Mar2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 0301634X
          Numbering:
            – Type: volume
              Value: 65
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Radiation & Environmental Biophysics
              Type: main
ResultId 1