Comparative outcomes of PFN vs PFNA2 nailing for osteoporotic unstable intertrochanteric fractures in the elderly.

Saved in:
Bibliographic Details
Title: Comparative outcomes of PFN vs PFNA2 nailing for osteoporotic unstable intertrochanteric fractures in the elderly.
Alternate Title: Resultados comparativos del empleo de clavos PFN frente a PFNA2 para fracturas osteoporóticas inestables intertrocantéricas en ancianos.
Authors: Dahuja, A.1, Khatri, K.1, Kaur, R.1 dr.rashmeet@gmail.com, Bansal, K.1, Singh, S.1
Source: Acta Ortopédica Mexicana. sep/oct2024, Vol. 38 Issue 5, p298-306. 9p.
Subjects: OSTEOPOROSIS, INTRAMEDULLARY rods, INTRAMEDULLARY fracture fixation, OLDER people, FEMUR
Abstract (English): Introduction: fixation of unstable intertrochanteric fractures presents a significant challenge, especially in the context of osteoporosis. Intramedullary implants have been established as superior to plate constructs. Our aim is to compare the complications and clinical outcomes of the Proximal Femur Nail (PFN) and Proximal Femur Nail Antirotation-2 (PFNA2) in managing unstable intertrochanteric fractures. Material and methods: a total of 212 patients meeting inclusion and exclusion criteria underwent fixation of trochanteric fractures using either a standard PFN (n = 110) or PFNA2 (n = 102). Their intraoperative and postoperative clinical and radiographic data were evaluated along with the quality of fixation. Data analysis was performed using the student's t-test, χ² test, and Mann-Whitney U test. Results: PFNA2 demonstrated more favorable outcomes compared to PFN in terms of a better intraoperative profile, functional outcomes (PFNA2: PFN = 82:75), and fewer implant-related complications. Significant issues in the PFN group included screw backout, guidewire breakage, and proximal protrusion of the nail tip. In contrast, locking mechanism failure and lateral screw prominence were significant problems in the PFNA2 group. Conclusion: PFNA2 is the preferred implant for managing osteoporotic unstable intertrochanteric fractures, given the bone's weak inherent tendency to secure the implant. [ABSTRACT FROM AUTHOR]
Abstract (Spanish): Introducción: la fijación de fracturas intertrocantéreas inestables presenta un desafío importante, especialmente en el contexto de la osteoporosis. Se ha demostrado que los implantes intramedulares son superiores a las construcciones con placas. Nuestro objetivo es comparar las complicaciones y los resultados clínicos del clavo de fémur proximal (PFN) y el clavo de fémur proximal antirotación-2 (PFNA2) en el tratamiento de fracturas intertrocantéreas inestables. Material y métodos: un total de 212 pacientes que cumplían con los criterios de inclusión y exclusión se sometieron a fijación de fracturas trocantéricas utilizando un PFN estándar (n = 110) o PFNA2 (n = 102). Se evaluaron sus datos clínicos y radiográficos intraoperatorios y postoperatorios junto con la calidad de la fijación. El análisis de los datos se realizó mediante la prueba t de Student, la prueba de χ² y la prueba U de Mann- Whitney. Resultados: PFNA2 demostró resultados más favorables en comparación con PFN en términos de un mejor perfil intraoperatorio, resultados funcionales (PFNA2: PFN = 82:75) y menos complicaciones relacionadas con los implantes. Los problemas importantes en el grupo PFN incluyeron el retroceso del tornillo, la rotura de la guía y la protrusión proximal de la punta del clavo. Por el contrario, la falla del mecanismo de bloqueo y la prominencia lateral del tornillo fueron problemas importantes en el grupo PFNA2. Conclusión: PFNA2 es el implante preferido para el tratamiento de fracturas intertrocantéreas inestables osteoporóticas, dada la débil tendencia inherente del hueso a asegurar el implante. [ABSTRACT FROM AUTHOR]
Copyright of Acta Ortopédica Mexicana is the property of Sociedad Mexicana de Ortopedia, AC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 179579479
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Comparative outcomes of PFN vs PFNA2 nailing for osteoporotic unstable intertrochanteric fractures in the elderly.
– Name: TitleAlt
  Label: Alternate Title
  Group: TiAlt
  Data: Resultados comparativos del empleo de clavos PFN frente a PFNA2 para fracturas osteoporóticas inestables intertrocantéricas en ancianos.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Dahuja%2C+A%2E%22">Dahuja, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Khatri%2C+K%2E%22">Khatri, K.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Kaur%2C+R%2E%22">Kaur, R.</searchLink><relatesTo>1</relatesTo><i> dr.rashmeet@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Bansal%2C+K%2E%22">Bansal, K.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Singh%2C+S%2E%22">Singh, S.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Acta+Ortopédica+Mexicana%22">Acta Ortopédica Mexicana</searchLink>. sep/oct2024, Vol. 38 Issue 5, p298-306. 9p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22OSTEOPOROSIS%22">OSTEOPOROSIS</searchLink><br /><searchLink fieldCode="DE" term="%22INTRAMEDULLARY+rods%22">INTRAMEDULLARY rods</searchLink><br /><searchLink fieldCode="DE" term="%22INTRAMEDULLARY+fracture+fixation%22">INTRAMEDULLARY fracture fixation</searchLink><br /><searchLink fieldCode="DE" term="%22OLDER+people%22">OLDER people</searchLink><br /><searchLink fieldCode="DE" term="%22FEMUR%22">FEMUR</searchLink>
– Name: Abstract
  Label: Abstract (English)
  Group: Ab
  Data: Introduction: fixation of unstable intertrochanteric fractures presents a significant challenge, especially in the context of osteoporosis. Intramedullary implants have been established as superior to plate constructs. Our aim is to compare the complications and clinical outcomes of the Proximal Femur Nail (PFN) and Proximal Femur Nail Antirotation-2 (PFNA2) in managing unstable intertrochanteric fractures. Material and methods: a total of 212 patients meeting inclusion and exclusion criteria underwent fixation of trochanteric fractures using either a standard PFN (n = 110) or PFNA2 (n = 102). Their intraoperative and postoperative clinical and radiographic data were evaluated along with the quality of fixation. Data analysis was performed using the student's t-test, χ² test, and Mann-Whitney U test. Results: PFNA2 demonstrated more favorable outcomes compared to PFN in terms of a better intraoperative profile, functional outcomes (PFNA2: PFN = 82:75), and fewer implant-related complications. Significant issues in the PFN group included screw backout, guidewire breakage, and proximal protrusion of the nail tip. In contrast, locking mechanism failure and lateral screw prominence were significant problems in the PFNA2 group. Conclusion: PFNA2 is the preferred implant for managing osteoporotic unstable intertrochanteric fractures, given the bone's weak inherent tendency to secure the implant. [ABSTRACT FROM AUTHOR]
– Name: Abstract
  Label: Abstract (Spanish)
  Group: Ab
  Data: Introducción: la fijación de fracturas intertrocantéreas inestables presenta un desafío importante, especialmente en el contexto de la osteoporosis. Se ha demostrado que los implantes intramedulares son superiores a las construcciones con placas. Nuestro objetivo es comparar las complicaciones y los resultados clínicos del clavo de fémur proximal (PFN) y el clavo de fémur proximal antirotación-2 (PFNA2) en el tratamiento de fracturas intertrocantéreas inestables. Material y métodos: un total de 212 pacientes que cumplían con los criterios de inclusión y exclusión se sometieron a fijación de fracturas trocantéricas utilizando un PFN estándar (n = 110) o PFNA2 (n = 102). Se evaluaron sus datos clínicos y radiográficos intraoperatorios y postoperatorios junto con la calidad de la fijación. El análisis de los datos se realizó mediante la prueba t de Student, la prueba de χ² y la prueba U de Mann- Whitney. Resultados: PFNA2 demostró resultados más favorables en comparación con PFN en términos de un mejor perfil intraoperatorio, resultados funcionales (PFNA2: PFN = 82:75) y menos complicaciones relacionadas con los implantes. Los problemas importantes en el grupo PFN incluyeron el retroceso del tornillo, la rotura de la guía y la protrusión proximal de la punta del clavo. Por el contrario, la falla del mecanismo de bloqueo y la prominencia lateral del tornillo fueron problemas importantes en el grupo PFNA2. Conclusión: PFNA2 es el implante preferido para el tratamiento de fracturas intertrocantéreas inestables osteoporóticas, dada la débil tendencia inherente del hueso a asegurar el implante. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Acta Ortopédica Mexicana is the property of Sociedad Mexicana de Ortopedia, AC and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=179579479
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.35366/117378
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 298
    Subjects:
      – SubjectFull: OSTEOPOROSIS
        Type: general
      – SubjectFull: INTRAMEDULLARY rods
        Type: general
      – SubjectFull: INTRAMEDULLARY fracture fixation
        Type: general
      – SubjectFull: OLDER people
        Type: general
      – SubjectFull: FEMUR
        Type: general
    Titles:
      – TitleFull: Comparative outcomes of PFN vs PFNA2 nailing for osteoporotic unstable intertrochanteric fractures in the elderly.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Dahuja, A.
      – PersonEntity:
          Name:
            NameFull: Khatri, K.
      – PersonEntity:
          Name:
            NameFull: Kaur, R.
      – PersonEntity:
          Name:
            NameFull: Bansal, K.
      – PersonEntity:
          Name:
            NameFull: Singh, S.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: sep/oct2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 23064102
          Numbering:
            – Type: volume
              Value: 38
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Acta Ortopédica Mexicana
              Type: main
ResultId 1