Minimally invasive cervical spine stabilization: A multicenter study of completely percutaneous pedicle screw-rod instrumentation.
Saved in:
| Title: | Minimally invasive cervical spine stabilization: A multicenter study of completely percutaneous pedicle screw-rod instrumentation. |
|---|---|
| Authors: | Klingler JH; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany., Wessels L; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany., Scholz C; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany., Schmidt TP; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany., Bertram U; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany., Hohenhaus M; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany., Hubbe U; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany., Jelgersma C; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany., Hecht N; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany., Watzlawick R; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany., Volz F; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany., Beck J; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany., Onken J; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany., Kothe R; Spine Department Schön Klinik Hamburg-Eilbek, Hamburg, Germany., Vajkoczy P; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany., Clusmann H; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany., Blume C; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany. |
| Source: | Brain & spine [Brain Spine] 2026 Feb 26; Vol. 6, pp. 105996. Date of Electronic Publication: 2026 Feb 26 (Print Publication: 2026). |
| Publication Type: | Journal Article |
| Journal Info: | Publisher: Elsevier B.V Country of Publication: Netherlands NLM ID: 9918470888906676 Publication Model: eCollection Cited Medium: Internet ISSN: 2772-5294 (Electronic) Linking ISSN: 27725294 NLM ISO Abbreviation: Brain Spine Subsets: PubMed not MEDLINE |
| Database: | MEDLINE Ultimate |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 41799387 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Minimally invasive cervical spine stabilization: A multicenter study of completely percutaneous pedicle screw-rod instrumentation. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Klingler+JH%22">Klingler JH</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.<br /><searchLink fieldCode="AU" term="%22Wessels+L%22">Wessels L</searchLink>; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.<br /><searchLink fieldCode="AU" term="%22Scholz+C%22">Scholz C</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.<br /><searchLink fieldCode="AU" term="%22Schmidt+TP%22">Schmidt TP</searchLink>; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.<br /><searchLink fieldCode="AU" term="%22Bertram+U%22">Bertram U</searchLink>; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.<br /><searchLink fieldCode="AU" term="%22Hohenhaus+M%22">Hohenhaus M</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.<br /><searchLink fieldCode="AU" term="%22Hubbe+U%22">Hubbe U</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.<br /><searchLink fieldCode="AU" term="%22Jelgersma+C%22">Jelgersma C</searchLink>; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.<br /><searchLink fieldCode="AU" term="%22Hecht+N%22">Hecht N</searchLink>; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.<br /><searchLink fieldCode="AU" term="%22Watzlawick+R%22">Watzlawick R</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.<br /><searchLink fieldCode="AU" term="%22Volz+F%22">Volz F</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.<br /><searchLink fieldCode="AU" term="%22Beck+J%22">Beck J</searchLink>; Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.<br /><searchLink fieldCode="AU" term="%22Onken+J%22">Onken J</searchLink>; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.<br /><searchLink fieldCode="AU" term="%22Kothe+R%22">Kothe R</searchLink>; Spine Department Schön Klinik Hamburg-Eilbek, Hamburg, Germany.<br /><searchLink fieldCode="AU" term="%22Vajkoczy+P%22">Vajkoczy P</searchLink>; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.<br /><searchLink fieldCode="AU" term="%22Clusmann+H%22">Clusmann H</searchLink>; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany.<br /><searchLink fieldCode="AU" term="%22Blume+C%22">Blume C</searchLink>; Spine Science Commission of the German Spine Society (DWG), Hamburg, Germany.; Department of Neurosurgery, RWTH Aachen University, Aachen, Germany. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%229918470888906676%22">Brain & spine</searchLink> [Brain Spine] 2026 Feb 26; Vol. 6, pp. 105996. <i>Date of Electronic Publication: </i>2026 Feb 26 (<i>Print Publication: </i>2026). – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Elsevier+B%2EV%22">Elsevier B.V </searchLink><i>Country of Publication: </i>Netherlands <i>NLM ID: </i>9918470888906676 <i>Publication Model: </i>eCollection <i>Cited Medium: </i>Internet <i>ISSN: </i>2772-5294 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2227725294%22">27725294 </searchLink><i>NLM ISO Abbreviation: </i>Brain Spine <i>Subsets: </i>PubMed not MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=41799387 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.bas.2026.105996 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 105996 Titles: – TitleFull: Minimally invasive cervical spine stabilization: A multicenter study of completely percutaneous pedicle screw-rod instrumentation. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Klingler JH – PersonEntity: Name: NameFull: Wessels L – PersonEntity: Name: NameFull: Scholz C – PersonEntity: Name: NameFull: Schmidt TP – PersonEntity: Name: NameFull: Bertram U – PersonEntity: Name: NameFull: Hohenhaus M – PersonEntity: Name: NameFull: Hubbe U – PersonEntity: Name: NameFull: Jelgersma C – PersonEntity: Name: NameFull: Hecht N – PersonEntity: Name: NameFull: Watzlawick R – PersonEntity: Name: NameFull: Volz F – PersonEntity: Name: NameFull: Beck J – PersonEntity: Name: NameFull: Onken J – PersonEntity: Name: NameFull: Kothe R – PersonEntity: Name: NameFull: Vajkoczy P – PersonEntity: Name: NameFull: Clusmann H – PersonEntity: Name: NameFull: Blume C IsPartOfRelationships: – BibEntity: Dates: – D: 26 M: 02 Text: 2026 Feb 26 Type: published Y: 2026 Identifiers: – Type: issn-electronic Value: 2772-5294 Numbering: – Type: volume Value: 6 Titles: – TitleFull: Brain & spine Type: main |
| ResultId | 1 |