Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures.

Saved in:
Bibliographic Details
Title: Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures.
Authors: Blot F (AUTHOR), Nitenberg G (AUTHOR), Chachaty E (AUTHOR), Raynard B (AUTHOR), Germann N (AUTHOR), Antoun S (AUTHOR), Laplanche A (AUTHOR), Brun-Buisson C (AUTHOR), Tancrede C (AUTHOR), Blot, F (AUTHOR), Nitenberg, G (AUTHOR), Chachaty, E (AUTHOR), Raynard, B (AUTHOR), Germann, N (AUTHOR), Antoun, S (AUTHOR), Laplanche, A (AUTHOR), Brun-Buisson, C (AUTHOR), Tancrède, C (AUTHOR)
Source: Lancet. 9/25/1999, Vol. 354 Issue 9184, p1071-1077. 7p.
Abstract: Background: A method of diagnosing catheter-related infection (CRI) without removing the catheter would be useful. An earlier positivity of central compared with peripheral venous-blood cultures may be associated with catheter-related bacteraemia. We evaluated prospectively the differential time to positivity (DTP) of paired blood cultures drawn simultaneously via the catheter hub and from a peripheral venous site.Methods: Over a 14-month period in an intensive-care unit of a cancer referral centre, simultaneous hub-blood and peripheral-blood cultures (a mean of two per patient) were obtained from patients with a suspected CRI. According to clinical criteria and quantitative culture of the catheter tip, cases were classified as CRI or sepsis of other origin. At least one pair of hub-blood and peripheral-blood cultures was obtained within 48 h before catheter removal, and we recorded the DTP between hub-blood and peripheral-blood cultures with an automatic device for detection of blood culture positivity.Findings: We analysed 93 catheters removed because of suspicion of CRI. In 28 episodes, the same micro-organisms were found in both hub-blood and peripheral-blood cultures. A diagnosis of definite bacteraemic CRI was made in 16 of the 17 patients in whom a positive hub-blood culture was detected at least 2 hours earlier than peripheral-blood culture. About half (9/17) of these episodes occurred in long-term (>30 days) devices. CRI was excluded in ten of the 11 patients with a DTP lower than 2 h. The DTP of paired blood cultures was significantly greater in patients with CRI than in others (p<10(-4)). A cut-off DTP value of 120 min had 91% specificity and 94% sensitivity for the diagnosis of CRI. Three of 17 episodes with only hub-blood culture positive were associated with CRI.Interpretation: This prospective study suggests that measurement of the differential time to positivity between hub-blood and peripheral-blood cultures is a simple and reliable tool for in-situ diagnosis of catheter-related sepsis in cancer patients. Further studies are needed to confirm these data for short-term catheters. [ABSTRACT FROM AUTHOR]
Copyright of Lancet is the property of Lancet and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Be the first to leave a comment!
You must be logged in first