Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel

The aim of this study was to compare real-time values of power and work obtained through BlueBrainTM and SmartCoachTM systems during flywheel leg press exercise using different inertias (loads). Eight sets of seven repetitions were performed at variable and maximum intensity for each inertia used (i...

Full description

Saved in:
Bibliographic Details
Main Author: Martínez Aranda, Luis Manuel
Published: 2016
Online Access: https://dialnet.unirioja.es/servlet/oaiart?codigo=5400861
_version_ 1867150430704762880
author Martínez Aranda, Luis Manuel
author_facet Martínez Aranda, Luis Manuel
description The aim of this study was to compare real-time values of power and work obtained through BlueBrainTM and SmartCoachTM systems during flywheel leg press exercise using different inertias (loads). Eight sets of seven repetitions were performed at variable and maximum intensity for each inertia used (i.e. 0.0125; 0.025; 0.0375; 0.05; 0.0625 and 0.075 kg*m2), with 2 minutes recovery between sets. Average power during concentric actions and total work (concentric-eccentric) were measured simultaneously using both systems. Data were analysed using a linear regression analysis and correlation procedures. Strong significant correlations were observed in average power results between both data acquisition systems for all individual inertias and intensities evaluated, as well as for overall data (r=.968; Sig.(2-tailed)=.000; R2=.937). In addition, work values showed clear significant correlations (r=.978; Sig.(2-tailed)=.000; R2=.957). Differences between devices oscillated over a range of 2.6-4.3%. The strong correlations found in power and work values seem to indicate that both data acquisition systems are similar and valid to estimate power and work during resistance exercises employing flywheel inertial technology. Thus, both devices may represent a helpful tool to control and follow up training using flywheel technology.
id 5400861
institution Dialnet
publishDate 2016
record_format oai_dc
spellingShingle Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel
Martínez Aranda, Luis Manuel
title Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel
title_full Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel
title_fullStr Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel
title_full_unstemmed Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel
title_short Comparación de dos dispositivos de medición de potencia y trabajo durante ejercicio de fuerza con tecnología inercial flywheel
url https://dialnet.unirioja.es/servlet/oaiart?codigo=5400861