The AIRMEX study - VOC measurements in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of the data

Saved in:
Bibliographic Details
Title: The AIRMEX study - VOC measurements in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of the data
Authors: Geiss, Otmar1, Giannopoulos, Georgios georgios.giannopoulos@jrc.ec.europa.eu, Tirendi, Salvatore1, Barrero-Moreno, Josefa1, Larsen, Bo R.1, Kotzias, Dimitrios1
Source: Atmospheric Environment. Jul2011, Vol. 45 Issue 22, p3676-3684. 9p.
Subject Terms: *Volatile organic compounds, *Indoor air quality, Measurement, Public buildings, Schools, Kindergarten facilities, Data analysis, Databases
Geographic Terms: Europe
Abstract: Abstract: Indoor and outdoor air concentrations as well as personal exposure concentrations of volatile organic compounds (VOCs) have been measured during 2003–2008 in public buildings, schools, kindergartens and private homes in eleven cities over Europe covering geographic areas in north, central and south Europe during different seasons within the frame of the AIRMEX (European Indoor Air Monitoring and Exposure assessment) study. A database is presented containing the results for 23 VOCs based upon approximately 1000 samples taken from 182 different working environments (offices, classrooms, waiting halls) in public buildings, schools and kindergartens, from 103 private homeplaces and from adult volunteers (148 samples). The statistical analysis of the data demonstrated that sources in the indoor environment are prevailing for most of the investigated VOCs with indoor/outdoor (I/O) concentration ratios following the order: hexanal ≈ d-limonene ≫ formaldehyde > acetone > 1-butoxy-2-propanol > acetaldehyde > propanal > 1-butanol > n-undecane > methylcyclohexane > n-dodecane. For aromatic hydrocarbons the main impact was shown to be penetration from outdoor air as indicated by I/O ratios near one and is characterised by significantly higher indoor as well as outdoor concentrations in the south of Europe with respect to the north. For the terpenes, the lowest indoor concentrations were measured during the warm season, which may be explained by higher ventilation rates and reactions with ozone penetrated from outdoor air. [Copyright &y& Elsevier]
Copyright of Atmospheric Environment is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: GreenFILE
Description
Abstract:Abstract: Indoor and outdoor air concentrations as well as personal exposure concentrations of volatile organic compounds (VOCs) have been measured during 2003–2008 in public buildings, schools, kindergartens and private homes in eleven cities over Europe covering geographic areas in north, central and south Europe during different seasons within the frame of the AIRMEX (European Indoor Air Monitoring and Exposure assessment) study. A database is presented containing the results for 23 VOCs based upon approximately 1000 samples taken from 182 different working environments (offices, classrooms, waiting halls) in public buildings, schools and kindergartens, from 103 private homeplaces and from adult volunteers (148 samples). The statistical analysis of the data demonstrated that sources in the indoor environment are prevailing for most of the investigated VOCs with indoor/outdoor (I/O) concentration ratios following the order: hexanal ≈ d-limonene ≫ formaldehyde > acetone > 1-butoxy-2-propanol > acetaldehyde > propanal > 1-butanol > n-undecane > methylcyclohexane > n-dodecane. For aromatic hydrocarbons the main impact was shown to be penetration from outdoor air as indicated by I/O ratios near one and is characterised by significantly higher indoor as well as outdoor concentrations in the south of Europe with respect to the north. For the terpenes, the lowest indoor concentrations were measured during the warm season, which may be explained by higher ventilation rates and reactions with ozone penetrated from outdoor air. [Copyright &y& Elsevier]
ISSN:13522310