A beamline‐compatible STED microscope for combined visible‐light and X‐ray studies of biological matter.
Saved in:
| Title: | A beamline‐compatible STED microscope for combined visible‐light and X‐ray studies of biological matter. |
|---|---|
| Authors: | Bernhardt, Marten1 (AUTHOR), Nicolas, Jan-David1 (AUTHOR), Osterhoff, Markus1 (AUTHOR), Mittelstädt, Haugen2 (AUTHOR), Reuss, Matthias2 (AUTHOR), Harke, Benjamin2 (AUTHOR), Wittmeier, Andrew1 (AUTHOR), Sprung, Michael3 (AUTHOR), Köster, Sarah1 (AUTHOR), Salditt, Tim1 (AUTHOR) tsaldit@gwdg.de |
| Source: | Journal of Synchrotron Radiation. Jul2019, Vol. 26 Issue 4, p1144-1151. 8p. |
| Subjects: | Holography, Small-angle X-ray scattering, X-rays, Stimulated emission, Microscopes, Storage rings |
| Geographic Terms: | Petra (Extinct city), Göttingen (Germany) |
| Abstract: | A dedicated stimulated emission depletion (STED) microscope had been designed and implemented into the Göttingen Instrument for Nano‐Imaging with X‐rays (GINIX) at the synchrotron beamline P10 of the PETRA III storage ring (DESY, Hamburg). The microscope was installed on the same optical table used for X‐ray holography and scanning small‐angle X‐ray scattering (SAXS). Scanning SAXS was implemented with the Kirkpatrick–Baez (KB) nano‐focusing optics of GINIX, while X‐ray holography used a combined KB and X‐ray waveguide optical system for full‐field projection recordings at a defocus position of the object. The STED optical axis was aligned (anti‐)parallel to the focused synchrotron beam and was laterally displaced from the KB focus. This close proximity between the STED and the X‐ray probe enabled in situ combined recordings on the same biological cell, tissue or any other biomolecular sample, using the same environment and mounting. Here, the instrumentation and experimental details of this correlative microscopy approach are described, as first published in our preceding work [Bernhardt et al. (2018), Nat. Commun.9, 3641], and the capabilities of correlative STED microscopy, X‐ray holography and scanning SAXS are illustrated by presenting additional datasets on cardiac tissue cells with labeled actin cytoskeleton. [ABSTRACT FROM AUTHOR] |
| Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 137375166 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A beamline‐compatible STED microscope for combined visible‐light and X‐ray studies of biological matter. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Bernhardt%2C+Marten%22">Bernhardt, Marten</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nicolas%2C+Jan-David%22">Nicolas, Jan-David</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Osterhoff%2C+Markus%22">Osterhoff, Markus</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mittelstädt%2C+Haugen%22">Mittelstädt, Haugen</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Reuss%2C+Matthias%22">Reuss, Matthias</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Harke%2C+Benjamin%22">Harke, Benjamin</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wittmeier%2C+Andrew%22">Wittmeier, Andrew</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sprung%2C+Michael%22">Sprung, Michael</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Köster%2C+Sarah%22">Köster, Sarah</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Salditt%2C+Tim%22">Salditt, Tim</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> tsaldit@gwdg.de</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Synchrotron+Radiation%22">Journal of Synchrotron Radiation</searchLink>. Jul2019, Vol. 26 Issue 4, p1144-1151. 8p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Holography%22">Holography</searchLink><br /><searchLink fieldCode="DE" term="%22Small-angle+X-ray+scattering%22">Small-angle X-ray scattering</searchLink><br /><searchLink fieldCode="DE" term="%22X-rays%22">X-rays</searchLink><br /><searchLink fieldCode="DE" term="%22Stimulated+emission%22">Stimulated emission</searchLink><br /><searchLink fieldCode="DE" term="%22Microscopes%22">Microscopes</searchLink><br /><searchLink fieldCode="DE" term="%22Storage+rings%22">Storage rings</searchLink> – Name: SubjectGeographic Label: Geographic Terms Group: Su Data: <searchLink fieldCode="DE" term="%22Petra+%28Extinct+city%29%22">Petra (Extinct city)</searchLink><br /><searchLink fieldCode="DE" term="%22Göttingen+%28Germany%29%22">Göttingen (Germany)</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: A dedicated stimulated emission depletion (STED) microscope had been designed and implemented into the Göttingen Instrument for Nano‐Imaging with X‐rays (GINIX) at the synchrotron beamline P10 of the PETRA III storage ring (DESY, Hamburg). The microscope was installed on the same optical table used for X‐ray holography and scanning small‐angle X‐ray scattering (SAXS). Scanning SAXS was implemented with the Kirkpatrick–Baez (KB) nano‐focusing optics of GINIX, while X‐ray holography used a combined KB and X‐ray waveguide optical system for full‐field projection recordings at a defocus position of the object. The STED optical axis was aligned (anti‐)parallel to the focused synchrotron beam and was laterally displaced from the KB focus. This close proximity between the STED and the X‐ray probe enabled in situ combined recordings on the same biological cell, tissue or any other biomolecular sample, using the same environment and mounting. Here, the instrumentation and experimental details of this correlative microscopy approach are described, as first published in our preceding work [Bernhardt et al. (2018), Nat. Commun.9, 3641], and the capabilities of correlative STED microscopy, X‐ray holography and scanning SAXS are illustrated by presenting additional datasets on cardiac tissue cells with labeled actin cytoskeleton. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=137375166 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1107/S1600577519004089 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 8 StartPage: 1144 Subjects: – SubjectFull: Holography Type: general – SubjectFull: Small-angle X-ray scattering Type: general – SubjectFull: X-rays Type: general – SubjectFull: Stimulated emission Type: general – SubjectFull: Microscopes Type: general – SubjectFull: Storage rings Type: general – SubjectFull: Petra (Extinct city) Type: general – SubjectFull: Göttingen (Germany) Type: general Titles: – TitleFull: A beamline‐compatible STED microscope for combined visible‐light and X‐ray studies of biological matter. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Bernhardt, Marten – PersonEntity: Name: NameFull: Nicolas, Jan-David – PersonEntity: Name: NameFull: Osterhoff, Markus – PersonEntity: Name: NameFull: Mittelstädt, Haugen – PersonEntity: Name: NameFull: Reuss, Matthias – PersonEntity: Name: NameFull: Harke, Benjamin – PersonEntity: Name: NameFull: Wittmeier, Andrew – PersonEntity: Name: NameFull: Sprung, Michael – PersonEntity: Name: NameFull: Köster, Sarah – PersonEntity: Name: NameFull: Salditt, Tim IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 07 Text: Jul2019 Type: published Y: 2019 Identifiers: – Type: issn-print Value: 09090495 Numbering: – Type: volume Value: 26 – Type: issue Value: 4 Titles: – TitleFull: Journal of Synchrotron Radiation Type: main |
| ResultId | 1 |