Title: Measurement of electron density distribution using heavy ion CT
Authors: Ohno, Y.1, Kohno, T.1 kohno@es.titech.ac.jp, Matsufuji, N.2, Kanai, T.2
Source: Nuclear Instruments & Methods in Physics Research Section A. Jun2004, Vol. 525 Issue 1/2, p279-283. 5p.
Subjects: Electrons, Heavy ions, Tomography, Clinical trials
Abstract: Clinical trials for tumor treatment using highly energetic heavy ions are now in progress at the HIMAC. In order to achieve the radiotherapy more precisely, it is important to know the distribution of the electron density in a human body. For this purpose, we have developed a broad beam heavy ion CT system. The performance, especially the electron density resolution, of this system is estimated in this work. Some kinds of the solution targets with the known electron densities were used as samples. The projection data were obtained using 12C of 290 MeV/u, 20Ne of 400 MeV/u and 4He of 150 MeV/u. The experimental values were in good agreement with the calculated values. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Clinical trials for tumor treatment using highly energetic heavy ions are now in progress at the HIMAC. In order to achieve the radiotherapy more precisely, it is important to know the distribution of the electron density in a human body. For this purpose, we have developed a broad beam heavy ion CT system. The performance, especially the electron density resolution, of this system is estimated in this work. Some kinds of the solution targets with the known electron densities were used as samples. The projection data were obtained using 12C of 290 MeV/u, 20Ne of 400 MeV/u and 4He of 150 MeV/u. The experimental values were in good agreement with the calculated values. [Copyright &y& Elsevier]
ISSN:01689002
DOI:10.1016/j.nima.2004.03.074