High-resolution alpha spectrometry from thick sources

Saved in:
Bibliographic Details
Title: High-resolution alpha spectrometry from thick sources
Authors: Pöllänen, R.1 roy.pollanen@stuk.fi, Siiskonen, T. teemu.siiskonen@stuk.fi, Vesterbacka, P.1
Source: Radiation Measurements. Sep2005, Vol. 39 Issue 5, p565-568. 4p.
Subjects: Alpha ray spectrometry, Membrane separation, Spectrum analysis, Monte Carlo method
Abstract: Abstract: Measurements, Monte Carlo simulations and imaging were used to study the degradation of the alpha particle energy spectrum caused by thick samples and thickness variations. Large local inhomogeneities were detected from the samples prepared by membrane filtration. Simulations were able to correctly produce alpha particle spectra. [Copyright &y& Elsevier]
Copyright of Radiation Measurements is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 17437765
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: High-resolution alpha spectrometry from thick sources
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Pöllänen%2C+R%2E%22">Pöllänen, R.</searchLink><relatesTo>1</relatesTo><i> roy.pollanen@stuk.fi</i><br /><searchLink fieldCode="AR" term="%22Siiskonen%2C+T%2E%22">Siiskonen, T.</searchLink><i> teemu.siiskonen@stuk.fi</i><br /><searchLink fieldCode="AR" term="%22Vesterbacka%2C+P%2E%22">Vesterbacka, P.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Radiation+Measurements%22">Radiation Measurements</searchLink>. Sep2005, Vol. 39 Issue 5, p565-568. 4p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Alpha+ray+spectrometry%22">Alpha ray spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Membrane+separation%22">Membrane separation</searchLink><br /><searchLink fieldCode="DE" term="%22Spectrum+analysis%22">Spectrum analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Abstract: Measurements, Monte Carlo simulations and imaging were used to study the degradation of the alpha particle energy spectrum caused by thick samples and thickness variations. Large local inhomogeneities were detected from the samples prepared by membrane filtration. Simulations were able to correctly produce alpha particle spectra. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Radiation Measurements is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=17437765
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.radmeas.2004.11.003
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 565
    Subjects:
      – SubjectFull: Alpha ray spectrometry
        Type: general
      – SubjectFull: Membrane separation
        Type: general
      – SubjectFull: Spectrum analysis
        Type: general
      – SubjectFull: Monte Carlo method
        Type: general
    Titles:
      – TitleFull: High-resolution alpha spectrometry from thick sources
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Pöllänen, R.
      – PersonEntity:
          Name:
            NameFull: Siiskonen, T.
      – PersonEntity:
          Name:
            NameFull: Vesterbacka, P.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 13504487
          Numbering:
            – Type: volume
              Value: 39
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Radiation Measurements
              Type: main
ResultId 1