Bibliographic Details
| Title: |
Performance studies with an ALICE TPC prototype |
| Authors: |
Antończyk, D.1, Baechler, J.2, Bramm, R.1, Campagnolo, R.2, Christiansen, P.2 peter.christiansen@risoe.dk, Frankenfeld, U.1, Gonzalez Gutierrez, C.2, Ivanov, M.3, Kowalski, M.4, Musa, L.2, Przybyla, A.1 |
| Source: |
Nuclear Instruments & Methods in Physics Research Section A. Sep2006, Vol. 565 Issue 2, p551-560. 10p. |
| Subjects: |
Electronics, Absorption, Nuclear physics, Particles |
| Abstract: |
Abstract: The main components of the ALICE TPC were tested with cosmic rays and beam particles. An Inner Readout Chamber was fully equipped with front end electronics including the DAQ chain, and operated in combination with a prototype field cage. The noise performance, baseline restoration, and characteristics of the ion tail for different gas mixtures were studied in detail. Furthermore, the spatial resolution for tracks and the particle identification performance over a momentum range from 1– were measured. The measured specific energy loss was compared with predictions from a photo absorption ionization model. [Copyright &y& Elsevier] |
|
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |