Optical Aptasensors for the Analysis of the Vascular Endothelial Growth Factor (VEGF).

Saved in:
Bibliographic Details
Title: Optical Aptasensors for the Analysis of the Vascular Endothelial Growth Factor (VEGF).
Authors: Freeman, Ronit1, Girsh, Julia1, Fang-ju Jou, Amily2, Ho, Ja-an Annie2, Hug, Thomas3, Dernedde, Jens3, Willner, Itamar1 willnea@vms.huji.ac.il
Source: Analytical Chemistry. 7/17/2012, Vol. 84 Issue 14, p6192-6198. 7p.
Subjects: Vascular endothelial growth factors, Biomarkers, Optical detectors, Fluorescence resonance energy transfer, Aptamers, Chemiluminescence assay, Quantum dots
Abstract: The vascular endothelial growth factor, VEGF, is an important biomarker for different diseases and clinical disorders. We present a series of optical aptasensor-based sensing platforms for VEGF that include the following: (i) A FRET-based sensor that involves the VEGF-induced separation of aptamer-functionalized quantum dots blocked by a quencher nucleic acid (detection limit 1 nM). (ii) A FRET-based sensor based on the VEGF-induced assembly of the aptamer subunits functionalized with QDs and a dye acceptor (Cy5), respectively (detection limit 12 nM). (iii) A chemiluminescence aptasensor based on VEGF-induced assembly of a hemin/G-quadruplex catalyst (detection limit 18 nM). (iv) A chemiluminescence aptasensor based on the VEGF-stimulated assembly of two aptamer subunits into the hemin/G-quadruplex catalyst (detection limit 2.6 nM). (v) A chemiluminescence resonance energy transfer (CRET) aptasensor based on the VEGF-induced assembly of a semiconductor QDs-hemin/G-quadruplex supramolecular structure (detection limit 875 pM). Furthermore, an amplified optical aptasensor system based on the Exonuclease III (Exo III) recycling of the VEGF analyte was developed. In this system, one aptamer subunit is modified at its 5′ and 3′ ends with QDs and a black hole quencher, respectively. The VEGF-induced self-assembly of the aptamer subunits result in the digestion of the quencher units and the autonomous recycling of the analyte, while triggering-on the luminescence of the QDs (detection limit 5 pM). The system was implemented to analyze VEGF in human sera samples. [ABSTRACT FROM AUTHOR]
Copyright of Analytical Chemistry is the property of American Chemical Society and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The vascular endothelial growth factor, VEGF, is an important biomarker for different diseases and clinical disorders. We present a series of optical aptasensor-based sensing platforms for VEGF that include the following: (i) A FRET-based sensor that involves the VEGF-induced separation of aptamer-functionalized quantum dots blocked by a quencher nucleic acid (detection limit 1 nM). (ii) A FRET-based sensor based on the VEGF-induced assembly of the aptamer subunits functionalized with QDs and a dye acceptor (Cy5), respectively (detection limit 12 nM). (iii) A chemiluminescence aptasensor based on VEGF-induced assembly of a hemin/G-quadruplex catalyst (detection limit 18 nM). (iv) A chemiluminescence aptasensor based on the VEGF-stimulated assembly of two aptamer subunits into the hemin/G-quadruplex catalyst (detection limit 2.6 nM). (v) A chemiluminescence resonance energy transfer (CRET) aptasensor based on the VEGF-induced assembly of a semiconductor QDs-hemin/G-quadruplex supramolecular structure (detection limit 875 pM). Furthermore, an amplified optical aptasensor system based on the Exonuclease III (Exo III) recycling of the VEGF analyte was developed. In this system, one aptamer subunit is modified at its 5′ and 3′ ends with QDs and a black hole quencher, respectively. The VEGF-induced self-assembly of the aptamer subunits result in the digestion of the quencher units and the autonomous recycling of the analyte, while triggering-on the luminescence of the QDs (detection limit 5 pM). The system was implemented to analyze VEGF in human sera samples. [ABSTRACT FROM AUTHOR]
ISSN:00032700
DOI:10.1021/ac3011473