Bibliographic Details
| Title: |
Enhancement of Non-Invasive Recording of Electroenterogram by Means of a Flexible Array of Concentric Ring Electrodes. |
| Authors: |
Garcia-Casado, J.1 jgarciac@eln.upv.es, Zena-Gimenez, V.1, Prats-Boluda, G.1, Ye-Lin, Y.1 |
| Source: |
Annals of Biomedical Engineering. Mar2014, Vol. 42 Issue 3, p651-660. 10p. 1 Color Photograph, 1 Diagram, 5 Charts, 3 Graphs. |
| Subjects: |
Noninvasive diagnostic tests, Electrocardiography, Ischemia, Laplacian matrices, Gastrointestinal diseases, Pacemaker cells |
| Abstract: |
Monitoring intestinal myoelectrical activity by electroenterogram (EEnG) would be of great clinical interest for diagnosing gastrointestinal pathologies and disorders. However, surface EEnG recordings are of very low amplitude and can be severely affected by baseline drifts and respiratory and electrocardiographic (ECG) interference. In this work, a flexible array of concentric ring electrodes was developed and tested to determine whether it can provide surface EEnG signals of better quality than bipolar recordings from conventional disc electrodes. With this aim, sixteen healthy subjects in a fasting state (>8 h) underwent recording. The capability of detecting intestinal pacemaker activity (slow wave) and the influence of physiological interferences were studied. The signals obtained from the concentric ring electrodes proved to be more robust to ECG and respiratory interference than those from conventional disc electrodes. The results also show that intestinal EEnG components such as the slow wave can be more easily identified by the proposed system based on a flexible array of concentric ring electrodes. The developed active electrode array could be a very valuable tool for non-invasive diagnosis of disease states such as ischemia and motility disorders of the small bowel which are known to alter the normal enteric slow wave activity. [ABSTRACT FROM AUTHOR] |
|
Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |