Agreement between video-based clinician-rated tools and patient-reported outcomes on gait assessment in individuals with multiple sclerosis.
Saved in:
| Title: | Agreement between video-based clinician-rated tools and patient-reported outcomes on gait assessment in individuals with multiple sclerosis. |
|---|---|
| Authors: | Özden, Fatih (AUTHOR), Özkeskin, Mehmet (AUTHOR), Ekici, Ece (AUTHOR), Yüceyar, Nur (AUTHOR) |
| Source: | Neurological Sciences. Jan2024, Vol. 45 Issue 1, p241-248. 8p. |
| Subjects: | Gait in humans, Multiple sclerosis |
| Abstract: | Purpose: To our knowledge, no studies compared the video-clinician-based tools and patient-reported questionnaires in assessing gait and balance in people with MS (pwMS). The present study investigated the correlation and agreement between video-clinician-based objective measurement tools and patient-reported outcome measures (PROMs) in gait and balance evaluation. Methods: A prospective cross-sectional study was conducted with 55 pwMS. Video analysis-based gait was evaluated by the Tinetti Gait Assessment (TGA), Gait Assessment and Intervention Tool (GAIT), and Functional Ambulation Classification Scale (FACS) by the clinician. Participants' self-reported gait and balance were assessed with the Multiple Sclerosis Walking Scale-12 (MSWS-12) and Activity-Specific Balance Confidence Scale (ABC). Results: There was a moderate positive correlation between ABC with TGA and FACS (r1: 0.552, r2: 0.510, p < 0.001). ABC was strongly correlated with GAIT (r: − 0.652, p < 0.001). A moderate positive correlation was observed between MSWS-12 with TGA and FACS (r1: − 0.575, r2: − 0.524, p < 0.001). In addition, there was a strong positive correlation between MSWS-12 and GAIT (r: − 0.652, p < 0.001). Clinician-rated tools and PROMs were within the agreement limits regarding the unstandardized beta values p < 0.001). Conclusions: Clinician-based gait and balance tools demonstrate consistent results with PROMs in pwMS. Considering the low cost and practical use of PROMs, in cases where video-based clinician-based measurements cannot be provided (time, space, and technical inadequacies), questionnaires can provide concordant results at moderate and severe levels compared with objective tools. [ABSTRACT FROM AUTHOR] |
| Copyright of Neurological Sciences is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Psychology and Behavioral Sciences Collection |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | Purpose: To our knowledge, no studies compared the video-clinician-based tools and patient-reported questionnaires in assessing gait and balance in people with MS (pwMS). The present study investigated the correlation and agreement between video-clinician-based objective measurement tools and patient-reported outcome measures (PROMs) in gait and balance evaluation. Methods: A prospective cross-sectional study was conducted with 55 pwMS. Video analysis-based gait was evaluated by the Tinetti Gait Assessment (TGA), Gait Assessment and Intervention Tool (GAIT), and Functional Ambulation Classification Scale (FACS) by the clinician. Participants' self-reported gait and balance were assessed with the Multiple Sclerosis Walking Scale-12 (MSWS-12) and Activity-Specific Balance Confidence Scale (ABC). Results: There was a moderate positive correlation between ABC with TGA and FACS (r1: 0.552, r2: 0.510, p < 0.001). ABC was strongly correlated with GAIT (r: − 0.652, p < 0.001). A moderate positive correlation was observed between MSWS-12 with TGA and FACS (r1: − 0.575, r2: − 0.524, p < 0.001). In addition, there was a strong positive correlation between MSWS-12 and GAIT (r: − 0.652, p < 0.001). Clinician-rated tools and PROMs were within the agreement limits regarding the unstandardized beta values p < 0.001). Conclusions: Clinician-based gait and balance tools demonstrate consistent results with PROMs in pwMS. Considering the low cost and practical use of PROMs, in cases where video-based clinician-based measurements cannot be provided (time, space, and technical inadequacies), questionnaires can provide concordant results at moderate and severe levels compared with objective tools. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 15901874 |
| DOI: | 10.1007/s10072-023-06983-7 |